ArticleInsights into imaging2012
MRI of the lung (1/3): methods.
Article in Insights into imaging, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 107 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Image-Based Structural and Functional Phenotyping of the COSYCONET Cohort Using MRI and CT (MR COPD)
Imaging Disease Progression in COPD (MR-COPDII)
Who cites it
107 citing papers in PubMed, 3 syntheses or guidelines pooled it.
- Functional hyperpolarized gas magnetic resonance imaging of idiopathic pulmonary fibrosis: a systematic review.La Radiologia medica · 2026Pooled it
- Longitudinal relaxation rate (Magma (New York, N.Y.) · 2025Pooled it
- The use of chest magnetic resonance imaging in interstitial lung disease: a systematic review.European respiratory review : an official journal of the European Respiratory Society · 2018Pooled it
- Feasibility of lung imaging at 0.55T for assessment of interstitial lung disease in patients with pulmonary sarcoidosis.European radiology · 2026Article
- Exercise-Induced Alterations in Lung Water Density in Heart Failure Using Single-Breath-Hold 3D Ultrashort Echo Time MRI.Journal of magnetic resonance imaging : JMRI · 2026Article
- Early detection of invasive lung cancer and multiorgan metastasis by a collagen-targeted protein MRI contrast agent.Science advances · 2026Article
- VQ-Wave: A Physics-Driven Spatiotemporal Deep Learning Approach for Noncontrast-Enhanced Lung Ventilation and Perfusion MRI.Magnetic resonance in medicine · 2026Article
- Magnetic Particle Imaging for Pulmonary Applications: Technological Advances, Biological Insights, and Clinical Translation.Bioengineering (Basel, Switzerland) · 2026Review
- Label-Free Lung MRI Segmentation via Misalignment-Aware Diffusion Translation.Journal of imaging informatics in medicine · 2026Article
- Recommendations for contouring of gross tumour volume for locally advanced lung cancer using magnetic resonance imaging.Physics and imaging in radiation oncology · 2026Article
- Optimized 3D UTE and ZTE MRI for high-resolution lung imaging: A comparative study.Magnetic resonance in medicine · 2026Article
- Multidimensional lung imaging: integrated preclinical platforms enabling the identification of translational biomarkers for pulmonary research.Respiratory research · 2026Review
- Pediatric pulmonary nodules: current state of knowledge, AI applications, and future directions.Pediatric radiology · 2026Review
- [Pulmonary imaging of cystic fibrosis with a focus on children and adolescents].Radiologie (Heidelberg, Germany) · 2025Review
- [Magnetic resonance imaging of the pediatric chest].Radiologie (Heidelberg, Germany) · 2025Review
- Pediatric Thoracic MRI: Safer, Sharper and Smarter Diagnostics.Children (Basel, Switzerland) · 2025Review
- An automated pipeline for computation and analysis of functional ventilation and perfusion lung MRI with matrix pencil decomposition: TrueLung.Zeitschrift fur medizinische Physik · 2025Article
- Thoracic MRI in Pediatric Oncology: Feasibility and Image Quality of Post-Contrast Free-Breathing Radial 3D T1 Weighted Imaging.Biomedicines · 2025Article
- Zero-echo time magnetic resonance imaging for visualizing pulmonary neoplasms.BMC medical imaging · 2025Article
- Plug-and-Play Self-Supervised Denoising for Pulmonary Perfusion MRI.Bioengineering (Basel, Switzerland) · 2025Article
47 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Proton magnetic resonance imaging (MRI) has recently emerged as a clinical tool to image the lungs. This paper outlines the current technical aspects of MRI pulse sequences, radiofrequency (RF) coils and MRI system requirements needed for imaging the pulmonary parenchyma and vasculature. Lung MRI techniques are presented as a "technical toolkit", from which MR protocols will be composed in the subsequent papers for comprehensive imaging of lung disease and function (parts 2 and 3). This paper is pitched at MR scientists, technicians and radiologists who are interested in understanding and establishing lung MRI methods. Images from a 1.5 T scanner are used for illustration of the sequences and methods that are highlighted. Main Messages • Outline of the hardware and pulse sequence requirements for proton lung MRI • Overview of pulse sequences for lung parenchyma, vascular and functional imaging with protons • Demonstration of the pulse-sequence building blocks for clinical lung MRI protocols.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.