Evidence map›Paper›PMID 22695947›Full record

ArticleInsights into imaging2012

Stereology: a novel technique for rapid assessment of liver volume.

Michael R Torkzad, Agneta Norén, Joel Kullberg

Open access · goldAbstract read
In one paragraph

Article in Insights into imaging, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Michael R TorkzadDepartment of Radiology, Oncology and Radiation Science, Section of Radiology, Akademiska sjukhuset, Uppsala University, Uppsala, Sweden, michael.torkzad@radiol.uu.se.
Agneta Norén
Joel Kullberg
Uppsala University Hospital · SEUppsala University · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe purpose of this study was to test the stereology method using several grid sizes for measuring liver volume and to find which grid provides an accurate estimate of liver volume. MATERIALS AND

methodsLiver volume was measured by volumetry in 41 sets of liver MRI. MRI was performed before and after different weight-reducing regimens. Grids of 3, 4, 5, and 6 cm were used to measure liver volume on different occasions by stereology. The liver volume and the changes in volume before and after treatment were compared between stereology and volumetry.

resultsThere was no significant difference in measurements between stereology methods and volumetry (p > 0.05). The mean differences in liver volume between stereology based on 3-, 4-, 5-, and 6-cm grids and volumetry were 37, 3, 132, and 23 mL, respectively, and the differences in measurement of liver volume change were 21, 2, 19, and 76 mL, respectively. The mean time required for measurement by stereology was 59-190 s.

conclusionStereology employing 3- and 4-cm grids can rapidly provide accurate results for measuring liver volume and changes in liver volume. MAIN MESSAGES: • Statistical methods can be used for measuring area/volume in radiology. • Measuring liver volume by stereology by 4-cm grids can be done in less than two minutes. • Follow-up of liver volume is highly accurate with stereological methods.

Identifiers

PMID22695947
PMCPMC3481078
OpenAlexW2145600443

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.