ArticleEuropean radiology2012
Advanced MR methods at ultra-high field (7 Tesla) for clinical musculoskeletal applications.
Article in European radiology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
26 citing papers in PubMed.
- Multi-center QA of ultrahigh-field systems.Magma (New York, N.Y.) · 2025Review
- Ex-vivo human pancreatic specimen evaluation by 7 Tesla MRI: a prospective radiological-pathological correlation study.La Radiologia medica · 2022Article
- 7 Tesla and Beyond: Advanced Methods and Clinical Applications in Magnetic Resonance Imaging.Investigative radiology · 2021Review
- Article
- Quantitative analysis of repaired rabbit supraspinatus tendons (± channeling) using magnetic resonance imaging at 7 Tesla.Quantitative imaging in medicine and surgery · 2021Article
- Feasibility of Hepatic Fat Quantification Using Proton Density Fat Fraction by Multi-Echo Chemical-Shift-Encoded MRI at 7T.Frontiers in physics · 2021Article
- Musculoskeletal MRI at 7 T: do we need more or is it more than enough?European radiology experimental · 2020Review
- [Update cartilage imaging of the small joints : Focus on high-field MRI].Der Radiologe · 2019Review
- Repeatability and reproducibility of cerebralBMC medical imaging · 2019Article
- Detection of early cartilage damage: feasibility and potential of gagCEST imaging at 7T.European radiology · 2018Article
- Knee dGEMRIC at 7 T: comparison against 1.5 T and evaluation of TBMC musculoskeletal disorders · 2018Article
- A new RF transmit coil for foot and ankle imaging at 7T MRI.Magnetic resonance imaging · 2018Article
- Evaluating the cartilage adjacent to the site of repair surgery with glycosaminoglycan-specific magnetic resonance imaging.International orthopaedics · 2017Article
- Article
- Topographical variations in zonal properties of canine tibial articular cartilage due to early osteoarthritis: a study using 7-T magnetic resonance imaging at microscopic resolution.Magma (New York, N.Y.) · 2016Article
- Diffusion-weighted imaging of breast tumours at 3 Tesla and 7 Tesla: a comparison.European radiology · 2016Article
- Comparison of muscle BOLD responses to arterial occlusion at 3 and 7 Tesla.Magnetic resonance in medicine · 2016Article
- New Imaging Methods for Non-invasive Assessment of Mechanical, Structural, and Biochemical Properties of Human Achilles Tendon: A Mini Review.Frontiers in physiology · 2016Review
- Ultra-High-Field MR Neuroimaging.AJNR. American journal of neuroradiology · 2015Review
- [Morphological and functional cartilage imaging].Der Orthopade · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
objectivesThis article provides an overview of the initial clinical results of musculoskeletal studies performed at 7 Tesla, with special focus on sodium imaging, new techniques such as chemical exchange saturation transfer (CEST) and T2* imaging, and multinuclear MR spectroscopy.
methodsSodium imaging was clinically used at 7 T in the evaluation of patients after cartilage repair procedures because it enables the GAG content to be monitored over time. Sodium imaging and T2* mapping allow insights into the ultra-structural composition of the Achilles tendon and help detect early disease. Chemical exchange saturation transfer was, for the first time, successfully applied in the clinical set-up at 7 T in patients after cartilage repair surgery. The potential of phosphorus MR spectroscopy in muscle was demonstrated in a comparison study between 3 and 7 T, with higher spectral resolution and significantly shorter data acquisition times at 7 T.
resultsThese initial clinical studies demonstrate the potential of ultra-high field MR at 7 T, with the advantage of significantly improved sensitivity for other nuclei, such as (23)Na (sodium) and (31)P (phosphorus).
conclusionsThe application of non-proton imaging and spectroscopy provides new insights into normal and abnormal physiology of musculoskeletal tissues, particularly cartilage, tendons, and muscles. KEY POINTS : • 7 T magnetic resonance provides significantly improved sensitivity for ( 23 ) Na and ( 31 ) P. • Initial clinical studies have now demonstrated ultra-high field MR operating at 7 T. • 7 T provides new insights into normal and abnormal physiology of musculoskeletal tissues.
Indexed as
Identifiers
22688127What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.