ArticleBiomicrofluidics2012
In situ pressure measurement within deformable rectangular polydimethylsiloxane microfluidic devices.
Article in Biomicrofluidics, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 57 citations in OpenAlex.
- A Review of the Application of Compliance Phenomenon in Particle Separation Within Microfluidic Systems.Micromachines · 2025Review
- Computational Fluid-Structure Interaction in Microfluidics.Micromachines · 2024Review
- Strain Sensor-Inserted Microchannel for Gas Viscosity Measurement.Biosensors · 2023Article
- 3D printed self-supporting elastomeric structures for multifunctional microfluidics.Science advances · 2020Article
- An Easy Method for Pressure Measurement in Microchannels Using Trapped Air Compression in a One-End-Sealed Capillary.Micromachines · 2020Article
- Flexible Microfluidics: Fundamentals, Recent Developments, and Applications.Micromachines · 2019Review
- Theory of the flow-induced deformation of shallow compliant microchannels with thick walls.Proceedings. Mathematical, physical, and engineering sciences · 2019Article
- Towards an Optimal Pressure Tap Design for Fluid-Flow Characterisation at Microscales.Materials (Basel, Switzerland) · 2019Article
- Biomimetic pulsatile flows through flexible microfluidic conduits.Biomicrofluidics · 2019Article
- Flow-induced deformation in a microchannel with a non-Newtonian fluid.Biomicrofluidics · 2018Article
- Physical Properties of PDMS (Polydimethylsiloxane) Microfluidic Devices on Fluid Behaviors: Various Diameters and Shapes of Periodically-Embedded Microstructures.Materials (Basel, Switzerland) · 2016Article
- The Deformation of Polydimethylsiloxane (PDMS) Microfluidic Channels Filled with Embedded Circular Obstacles under Certain Circumstances.Molecules (Basel, Switzerland) · 2016Article
- Characterizing the Deformation of the Polydimethylsiloxane (PDMS) Membrane for Microfluidic System through Image Processing.Micromachines · 2016Article
- Deformation properties between fluid and periodic circular obstacles in polydimethylsiloxane microchannels: Experimental and numerical investigations under various conditions.Biomicrofluidics · 2013Article
- Experimental characterisation of a novel viscoelastic rectifier design.Biomicrofluidics · 2012Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this paper, we present a simple procedure to incorporate commercially available external pressure transducers into existing microfluidic devices, to monitor pressure-drop in real-time, with minimal design modifications to pre-existing channel designs. We focus on the detailed fabrication steps and assembly to make the process straightforward and robust. The work presented here will benefit those interested in adding pressure drop measurements in polydimethylsiloxane (PDMS) based microchannels without having to modify existing channel designs or requiring additional fabrication steps. By using three different devices with varying aspect ratio channels ([Formula: see text], width/depth), we demonstrate that our approach can easily be adapted into existing channel designs inexpensively. Furthermore, our approach can achieve steady state measurements within a matter of minutes (depending on the fluid) and can easily be used to investigate dynamic pressure drops. In order to validate the accuracy of the measured pressure drops within the three different aspect ratio devices, we compared measured pressure drops of de-ionized water and a 50 wt. % glycerol aqueous solution to four different theoretical expressions. Due to the deformability of PDMS, measured pressure drops were smaller than those predicted by the rigid channel theories (plate and rectangular). Modification of the rigid channel theories with a deformability parameter α provided better fits to the measured data. The elastic rectangular expression developed in this paper does not have a geometric restriction and is better suited for microchannels with a wider range of aspect ratios.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.