ArticleBiomicrofluidics2012
Dielectrophoretic capture voltage spectrum for measurement of dielectric properties and separation of cancer cells.
Article in Biomicrofluidics, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
34 citing papers in PubMed, 96 citations in OpenAlex.
- Dielectrophoresis and ζ-potential as potential low-cost complements to patch clamp for measurement of cell electrophysiology.PloS one · 2026Article
- Dielectrophoresis-assisted microfluidic device for high-precision and periodic single-cell capture and release.Journal of nanobiotechnology · 2025Article
- Development of 2D Microfluidics Surface with Low-Frequency Electric Fields for Cell Separation Applications.Sensors (Basel, Switzerland) · 2025Article
- Experimentally profiling dielectric properties of Escherichia coli and Staphylococcus aureus by movement velocity and force.Scientific reports · 2025Article
- Article
- Evaluating refrigeration and antibiotic treatment for maintaining urine electrophysiology.PloS one · 2025Article
- Numerical study on a facing electrode configuration dielectrophoresis microfluidic system for efficient biological cell separation.Scientific reports · 2024Article
- Dielectrophoretic profiling of erythrocytes to study the impacts of metabolic stress, temperature, and storage duration utilizing a point-and-planar microdevice.Scientific reports · 2023Article
- Topological damping in an ultrafast giant cell.Proceedings of the National Academy of Sciences of the United States of America · 2023Article
- A Novel Hybrid Platform for Live/Dead Bacteria Accurate Sorting by On-Chip DEP Device.International journal of molecular sciences · 2023Article
- HT-29 Colon Cancer Cell Electromanipulation and Assessment Based on Their Electrical Properties.Micromachines · 2022Article
- Implementation of an Integrated Dielectrophoretic and Magnetophoretic Microfluidic Chip for CTC Isolation.Biosensors · 2022Article
- Evaluation of Isomotive Insulator-Based Dielectrophoretic Device by Measuring the Particle Velocity.Sensors (Basel, Switzerland) · 2022Article
- Dielectrophoretic and Electrical Impedance Differentiation of Cancerous Cells Based on Biophysical Phenotype.Biosensors · 2021Article
- Investigation of a two-step device implementing magnetophoresis and dielectrophoresis for separation of circulating tumor cells from blood cells.Engineering in life sciences · 2020Article
- Determination of Dielectric Properties of Cells using AC Electrokinetic-based Microfluidic Platform: A Review of Recent Advances.Micromachines · 2020Review
- Scalable Parallel Manipulation of Single Cells Using Micronozzle Array Integrated with Bidirectional Electrokinetic Pumps.Micromachines · 2020Article
- Development and Clinical Prospects of Techniques to Separate Circulating Tumor Cells from Peripheral Blood.Cancer management and research · 2020Review
- Direct enrichment of pathogens from physiological samples of high conductivity and viscosity using H-filter and positive dielectrophoresis.Biomicrofluidics · 2018Article
- Accurate Extraction of the Self-Rotational Speed for Cells in an Electrokinetics Force Field by an Image Matching Algorithm.Micromachines · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this paper, a new dielectrophoresis (DEP) method based on capture voltage spectrum is proposed for measuring dielectric properties of biological cells. The capture voltage spectrum can be obtained from the balance of dielectrophoretic force and Stokes drag force acting on the cell in a microfluidic device with fluid flow and strip electrodes. The method was demonstrated with the measurement of dielectric properties of human colon cancer cells (HT-29 cells). From the capture voltage spectrum, the real part of Clausius-Mossotti factor of HT-29 cells for different frequencies of applied electric field was obtained. The dielectric properties of cell interior and plasma membrane were then estimated by using single-shell dielectric model. The cell interior permittivity and conductivity were found to be insensitive to changes in the conductivity of the medium in which the cells are suspended, but the measured permittivity and conductivity of cell membrane were found to increase with the increase of medium conductivity. In addition, the measurement of capture voltage spectrum was found to be useful in providing the optimum operating conditions for separating HT-29 cells from other cells (such as red blood cells) using dielectrophoresis.