Evidence map›Paper›PMID 22648118›Full record

ArticleSurgical endoscopy2012

Magnetically anchored camera and percutaneous instruments maintain triangulation and improve cosmesis compared with single-site and conventional laparoscopic cholecystectomy.

Nabeel A Arain, Luisangel Rondon, Deborah C Hogg, Jeffrey A Cadeddu, Richard Bergs, Raul Fernandez, Daniel J Scott

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Nabeel A ArainDepartment of Surgery, The University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-9156, USA. Nabeel.arain@UTsouthwestern.edu
Luisangel Rondon
Deborah C Hogg
Jeffrey A Cadeddu
Richard Bergs
Raul Fernandez
Daniel J Scott
The University of Texas Southwestern Medical Center · USRobotics Research (United States) · USSouthwestern Medical Center · USThe University of Texas at Arlington · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study evaluated operative outcomes and ergonomics for a magnetic camera (MAGS) used in conjunction with percutaneous instruments [percutaneous surgical set (PSS)] compared with single-site laparoscopic (SSL) and conventional laparoscopic (LAP) cholecystectomy techniques.

methodsFour surgical trainees each performed three porcine cholecystectomies using three randomized techniques including MAGS/PSS, SSL, and LAP. The operative outcomes, procedure-specific ratings (1-5 scale; 1 = superior), workload (1-10 scale; 1 = superior), and global impressions (1-10 scale; 10 = superior) were recorded. Comparisons used analysis of variance (ANOVA) on ranks (Kruskal-Wallis), and p values lower than 0.05 were considered significant.

resultsThe operative outcomes were similar except for significantly higher blood loss with SSL (16.3 ± 10.3) versus LAP (2.8 ± 1.5; p < 0.05) but not with MAGS/PSS (4.8 ± 3.8). Several inadvertent tissue-damaging events occurred with SSL but not with MAGS/PSS or LAP. The incision was significantly shorter with MAGS/PSS (29.3 ± 2.8 mm) and SSL (29.3 ± 2.5 mm) than with LAP (48.0 ± 3.6 mm; p < 0.05). Compared with SSL (3.6 ± 0.5), the procedure-specific ratings significantly favored MAGS/PSS (2.8 ± 0.4) and LAP (1.7 ± 0.2; p < 0.05). Ergonomics and technical challenges both were rated significantly inferior with SSL (4.3 ± 1.0 and 3.8 ± 0.5, respectively) versus LAP (1.5 ± 0.6 and 2.0 ± 0.8, respectively; p < 0.05) but not with MAGS/PSS (2.5 ± 1.0 and 3.0 ± 0.8, respectively). Both MAGS/PSS (4.5 ± 0.5) and SSL (4.8 ± 1.0) were associated with a significantly greater workload than LAP (2.5 ± 0.6; p < 0.05). Global impression ratings were significantly higher for LAP (8.7 ± 1.3) versus SSL (5.8 ± 2.0; p < 0.05) but not for MAGS/PSS (7.1 ± 1.8). Cosmesis was significantly better with MAGS/PSS (9.5 ± 0.6) versus LAP (6.5 ± 2.4; p < 0.05) but not with SSL (8.8 ± 1.3).

conclusionThe MAGS/PSS technique allows better triangulation and fewer technical difficulties than SSL and better cosmesis than LAP. Further development of these devices is warranted.

Indexed as

Cholecystectomy, LaparoscopicEquipment DesignHumansMagnets

Identifiers

PMID22648118
OpenAlexW2000532871

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.