ArticlePhysiological measurement2012
A miniature bidirectional telemetry system for in vivo gastric slow wave recordings.
Article in Physiological measurement, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 29 citations in OpenAlex.
- Clinical application and research progress of extracellular slow wave recording in the gastrointestinal tract.World journal of gastrointestinal surgery · 2022Review
- An Implantable Inductive Near-Field Communication System with 64 Channels for Acquisition of Gastrointestinal Bioelectrical Activity.Sensors (Basel, Switzerland) · 2019Article
- A Miniature Configurable Wireless System for Recording Gastric Electrophysiological Activity and Delivering High-Energy Electrical Stimulation.IEEE journal on emerging and selected topics in circuits and systems · 2018Article
- Functional physiology of the human terminal antrum defined by high-resolution electrical mapping and computational modeling.American journal of physiology. Gastrointestinal and liver physiology · 2016Article
- Multi-channel wireless mapping of gastrointestinal serosal slow wave propagation.Neurogastroenterology and motility · 2015Article
- Gastric arrhythmias in gastroparesis: low- and high-resolution mapping of gastric electrical activity.Gastroenterology clinics of North America · 2015Review
- Slow wave conduction patterns in the stomach: from Waller's foundations to current challenges.Acta physiologica (Oxford, England) · 2015Review
- A system and method for online high-resolution mapping of gastric slow-wave activity.IEEE transactions on bio-medical engineering · 2014Article
- Recent progress in gastric arrhythmia: pathophysiology, clinical significance and future horizons.Clinical and experimental pharmacology & physiology · 2014Article
- Mapping and modeling gastrointestinal bioelectricity: from engineering bench to bedside.Physiology (Bethesda, Md.) · 2013Review
- Experimental and Automated Analysis Techniques for High-resolution Electrical Mapping of Small Intestine Slow Wave Activity.Journal of neurogastroenterology and motility · 2013Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 2 countries.
Funding
Abstract
Stomach contractions are initiated and coordinated by an underlying electrical activity (slow waves), and electrical dysrhythmias accompany motility diseases. Electrical recordings taken directly from the stomach provide the most valuable data, but face technical constraints. Serosal or mucosal electrodes have cables that traverse the abdominal wall, or a natural orifice, causing discomfort and possible infection, and restricting mobility. These problems motivated the development of a wireless system. The bidirectional telemetric system constitutes a front-end transponder, a back-end receiver and a graphical userinter face. The front-end module conditions the analogue signals, then digitizes and loads the data into a radio for transmission. Data receipt at the backend is acknowledged via a transceiver function. The system was validated in a bench-top study, then validated in vivo using serosal electrodes connected simultaneously to a commercial wired system. The front-end module was 35 × 35 × 27 mm3 and weighed 20 g. Bench-top tests demonstrated reliable communication within a distance range of 30 m, power consumption of 13.5 mW, and 124 h operation when utilizing a 560 mAh, 3 V battery. In vivo,slow wave frequencies were recorded identically with the wireless and wired reference systems (2.4 cycles min−1), automated activation time detection was modestly better for the wireless system (5% versus 14% FP rate), and signal amplitudes were modestly higher via the wireless system (462 versus 3 86μV; p<0.001). This telemetric system for slow wave acquisition is reliable,power efficient, readily portable and potentially implantable. The device will enable chronic monitoring and evaluation of slow wave patterns in animals and patients.0967-3334/
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.