ArticleClinical research in cardiology : official journal of the German Cardiac Society2012
Assessment of an asymmetrical coating stent with sirolimus released from ablumial matrix in porcine model.
Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 12 citations in OpenAlex.
- Polymeric Nanomaterials for Atherosclerosis Diagnosis and Treatment.Polymer science & technology (Washington, D.C.) · 2025Review
- Recent advances in surface functionalization of cardiovascular stents.Bioactive materials · 2025Review
- Phenotypic transformation of smooth muscle cells from porcine coronary arteries is associated with connexin 43.Molecular medicine reports · 2016Article
- Spatio-Temporal Control of LbL Films for Biomedical Applications: From 2D to 3D.Advanced healthcare materials · 2015Review
- Safety and efficacy of different stent types for the endovascular therapy of extracranial vertebral artery disease.Clinical research in cardiology : official journal of the German Cardiac Society · 2014Article
- First in vitro and in vivo results of an anti-human CD133-antibody coated coronary stent in the porcine model.Clinical research in cardiology : official journal of the German Cardiac Society · 2013Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 6 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundDelayed endothelialization contributes to stent thrombosis of current drug-eluting stents. The asymmetrical coating technique provides an anti-proliferative effect abluminally without affecting luminal endothelialization. Layer-by-layer self-assembled chitosan/heparin (C/H LBL) has been proved to promote re-endothelialization. A novel stent system, C/H LBL coated luminally and sirolimus released abluminally (C/H LBL-SES), was fabricated.
methodsBare metal stents (BMS), traditionally circumferential sirolimus-eluting stents (SES), and C/H LBL-SES were implanted into porcine coronary arteries. At the 7, 14 and 28 days follow-up (FU), angiography, intravascular ultrasound (IVUS), vasomotor function induced by acetylcholine (Ach), scanning-electron microscopy and histopathology were performed. Remodeling index (RI) was based on IVUS and defined as cross-sectional area (CSA) of vessel at in-stent segment divided by CSA of reference vessel and expressed as a percentage with a normal range from 0.95 to 1.05.
resultsThirty-eight mini pigs were enrolled and 74 stents (BMS = 23, C/H LBL = 28, SES = 23) were implanted in this study. At 28 days after implantation, the diameter stenosis of C/H LBL-SES by quantitative coronary angiography was 18.8 ± 2.5 %, the area stenosis by histomorphometry was 24.2 ± 2.9 %, which were comparable to that of SES and superior to BMS. At 14 days, re-endothelialization of C/H LBL-SES was almost completed, while only about 50 % of surface of SES was covered by endothelium. At 7, 14 and 28 days FU, although C/H LBL-SES suffered a greater vasoconstriction induced by Ach infusion than BMS (P < 0.05), it behaved better than SES (P < 0.01). No sign of stent malapposition was detected, while RI was within the normal range by IVUS. No acute or subacute thrombotic events occurred in all three groups.
conclusionsThe asymmetrically designed C/H LBL-SES successfully inhibited neointima hyperplasia, while diminishing vasoconstriction after Ach-stress. Endothelialization of C/H LBL-SES was less affected compared with traditionally circumferentially coated SES.
Indexed as