ArticleIEEE transactions on bio-medical engineering2012
A preclinical system prototype for focused microwave thermal therapy of the breast.
Article in IEEE transactions on bio-medical engineering, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 142 citations in OpenAlex.
- Microwave technologies for biomedical diagnosis and therapy: advances, challenges, and perspectives.Mikrochimica acta · 2026Review
- Microwave Foreign Object Detection in a Lossy Medium Using a Planar Array Antenna.Sensors (Basel, Switzerland) · 2025Article
- Improvement of Phased Antenna Array Applied in Focused Microwave Breast Hyperthermia.Sensors (Basel, Switzerland) · 2024Article
- Targeted Nanoparticles: the Smart Way for the Treatment of Colorectal Cancer.AAPS PharmSciTech · 2024Review
- Body Boundary Measurement Using Multiple Line Lasers for a Focused Microwave Thermotherapy System: A Proof-of-Concept Study.Sensors (Basel, Switzerland) · 2023Article
- Diatom-Based Nanomedicine for Colorectal Cancer Treatment: New Approaches for Old Challenges.Marine drugs · 2023Review
- Differential Evolution Optimization of Microwave Focused Hyperthermia Phased Array Excitation for Targeted Breast Cancer Heating.Sensors (Basel, Switzerland) · 2023Article
- Design of Ultra-Wideband Phased Array Applicator for Breast Cancer Hyperthermia Therapy.Sensors (Basel, Switzerland) · 2023Article
- Recent advances in nanomedicine preparative methods and their therapeutic potential for colorectal cancer: a critical review.Frontiers in oncology · 2023Review
- Nanotechnology for colorectal cancer detection and treatment.World journal of gastroenterology · 2022Review
- Rotationally Adjustable Hyperthermia Applicators: A Computational Comparative Study of Circular and Linear Array Applicators.Diagnostics (Basel, Switzerland) · 2022Article
- Antenna Excitation Optimization with Deep Learning for Microwave Breast Cancer Hyperthermia.Sensors (Basel, Switzerland) · 2022Article
- Promising Therapeutic Strategies for Colorectal Cancer Treatment Based on Nanomaterials.Pharmaceutics · 2022Review
- An Electromagnetic Time-Reversal Imaging Algorithm for Moisture Detection in Polymer Foam in an Industrial Microwave Drying System.Sensors (Basel, Switzerland) · 2021Article
- Microwave Sensors for Breast Cancer Detection.Sensors (Basel, Switzerland) · 2018Review
- Real-time microwave imaging of differential temperature for thermal therapy monitoring.IEEE transactions on bio-medical engineering · 2014Article
- Perspectives of breast cancer thermotherapies.Journal of Cancer · 2014Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
A preclinical prototype of a transcutaneous thermal therapy system has been developed for the targeted treatment of breast cancer cells using focused microwaves as an adjuvant to radiation, chemotherapy, and high-intensity-focused ultrasound. The prototype system employs a 2-D array of tapered microstrip patch antennas operating at 915 MHz to focus continuous-wave microwave energy transcutaneously into the pendent breast suspended in a coupling medium. Prior imaging studies are used to ascertain the material properties of the breast tissue, and these data are incorporated into a multiphysics model. Time-reversal techniques are employed to find a solution (relative amplitudes and phase) for focusing at a given location. Modeling tests of this time-reversal focusing method have been performed, which demonstrate good targeting accuracy within heterogeneous breast tissue. Experimental results using the laboratory prototype to perform focused heating in tissue-mimicking gelatin phantoms have demonstrated 1.5-cm-diameter focal spot sizes and differential heating at the desired focus sufficient to achieve an antitumor effect confined to the target region.
Indexed as
Identifiers
What OpenQuestion holds