Evidence map›Paper›PMID 22608717›Full record

ArticleThe Annals of thoracic surgery2012

Cannulation strategy for aortic arch reconstruction using deep hypothermic circulatory arrest.

Diane de Zélicourt, Philsub Jung, Marc Horner, Kerem Pekkan, Kirk R Kanter, Ajit P Yoganathan

Open access · greenAbstract read
In one paragraph

Article in The Annals of thoracic surgery, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.6field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 14 citations in OpenAlex.

  1. Development of idealized human aortic models forFrontiers in cardiovascular medicine · 2024
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 1 country.

Diane de ZélicourtWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0535, USA.
Philsub Jung
Marc Horner
Kerem Pekkan
Kirk R Kanter
Ajit P Yoganathan
The Wallace H. Coulter Department of Biomedical Engineering · USAnsys (United States) · USCarnegie Mellon University · USEmory University · USGeorgia Institute of Technology · US

Funding

Improving Flow Dynamics in Fontan SurgeriesR01HL067622 · NHLBI · GEORGIA INSTITUTE OF TECHNOLOGY · PI YOGANATHAN, AJIT P · 2002 to 2006
$5.2M
NHLBI NIH HHS HL-67622NHLBI NIH HHS R01 HL067622
6 · The paper itself

Abstract

backgroundAortic arch reconstruction in neonates is commonly performed using deep hypothermic circulatory arrest. However, concerns have arisen regarding potential adverse neurologic outcomes from this complex procedure, raising questions about the best arterial cannulation approach for cerebral perfusion and effective systemic hypothermia. In this study, we use computational fluid dynamics to investigate the effect of different cannulation strategies in neonates.

methodsWe used a realistic template of a hypoplastic neonatal aorta as the base geometry to investigate four cannulation options: (1) right innominate artery, (2) innominate root, (3) patent ductus arteriosus (PDA), or (4) innominate root and PDA. Performance was evaluated according to the numerically predicted cerebral and systemic flow distributions compared with physiologic perfusion under neonatal conditions.

resultsThe four cannulation strategies were associated with different local hemodynamics; however, this did not translate into any significant effect on the measured flow distributions. The largest difference only represented 0.8% of the cardiac output and was measured in the innominate artery, which received 23.2% of the cardiac output in option 3 vs 24% in option 4. Pulmonary artery snaring benefited all systemic vessels uniformly.

conclusionsBecause of the very high vascular resistances in neonates, downstream vascular resistances dictated flow distribution to the different vascular beds rather than the cannulation strategy, allowing the surgical team to choose their method of preference. However, patients with aortic coarctation warrant further investigation and will most likely benefit from a 2-cannulae approach (option 4).

Indexed as

Circulatory Arrest, Deep Hypothermia InducedAorta, ThoracicCardiac Surgical ProceduresCatheterizationHumansModels, Anatomic

Identifiers

PMID22608717
PMCPMC3631598
OpenAlexW2144427590

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.