Evidence map›Paper›PMID 22581034›Full record

ArticleASAIO journal (American Society for Artificial Internal Organs : 1992)

Hemodynamic design requirements for in-series thoracic artificial lung attachment in a model of pulmonary hypertension.

Begum Akay, Julie A Foucher, Daniele Camboni, Kelly L Koch, Ayushi Kawatra, Keith E Cook

Open access · greenAbstract read
In one paragraph

Article in ASAIO journal (American Society for Artificial Internal Organs : 1992). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 9 citations in OpenAlex.

  1. Low-Resistance, Concentric-Gated Pediatric Artificial Lung for End-Stage Lung Failure.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2020
    Article
  2. Early in vivo experience with the pediatric continuous-flow total artificial heart.The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2018
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Design and in vitro assessment of an improved, low-resistance compliant thoracic artificial lung.ASAIO journal (American Society for Artificial Internal Organs : 1992)
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Begum AkayDepartment of Surgery, University of Michigan, Ann Arbor, USA.
Julie A Foucher
Daniele Camboni
Kelly L Koch
Ayushi Kawatra
Keith E Cook
University of Michigan–Ann Arbor · US

Funding

Compliant Thoracic Artificial LungsR01HL089043 · NHLBI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI COOK, KEITH E · 2009 to 2017
$4.2M
NHLBI NIH HHS R01 HL089043
6 · The paper itself

Abstract

Recent thoracic artificial lung (TAL) prototypes have impedances lower than the natural lung. With these devices, proximal pulmonary artery (PA) to distal PA TAL attachment may be possible in patients without right ventricular dysfunction. This study examined the relationship between pulmonary system impedance and cardiac output (CO) to create TAL design constraints. A circuit with adjustable resistance and compliance (C) was attached in a PA-PA fashion with the pulmonary circulation of seven sheep with chronic pulmonary hypertension. The pulmonary system zeroth harmonic impedance modulus (Z(0)) was increased by 1, 2.5, and 4 mmHg/(L/min) above baseline. At each Z(0), C was set to 0, 0.34, and 2.1 ml/mmHg. The change in pulmonary system zeroth and first harmonic impedance moduli (ΔZ(0) and ΔZ(1)), the percent change in CO (%ΔCO), and the inlet and outlet anastomoses resistances were calculated for each situation. Results indicate that ΔZ(0) (p < 0.001) but not ΔZ(1) (p = 0.5) had a significant effect on %ΔCO and that %ΔCO = -7.45*ΔZ(0) (R(2) = 0.57). Inlet and outlet anastomoses resistances averaged 0.77 ± 0.16 and 0.10 ± 0.19 mmHg/(L/min), respectively, and the relationship between %ΔCO and TAL resistance, R(T), in mmHg/(L/min) was determined to be %ΔCO = -(7.45f)×(R(T) + 0.87), in which f = the fraction of CO through the TAL. Thus, newer TAL designs can limit %ΔCO to less than 10% if f < 0.75.

Indexed as

HemodynamicsAnimalsArtificial OrgansDisease Models, AnimalEquipment DesignHumansHypertension, PulmonaryLungModels, StatisticalModels, TheoreticalPressureProsthesis DesignPulmonary ArteryPulmonary CirculationSheepThorax

Identifiers

PMID22581034
PMCPMC3604742
OpenAlexW2083038663

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.