Evidence map›Paper›PMID 22570718›Full record

ArticlePloS one2012

Development and utility of an internal threshold control (ITC) real-time PCR assay for exogenous DNA detection.

Weiyi Ni, Caroline Le Guiner, Philippe Moullier, Richard O Snyder

Registry-linked trialAbstract read
In one paragraph

Article in PloS one, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03548766 (Using DNA-Typing and Erythrocyte Microparticle Analysis to Detect Homologous/Autologous Blood Doping- a Transfusion Study), which is not on this map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03548766 phase3unknown statusnot on this mapstarted 2018, after this paper: background citation

Using DNA-Typing and Erythrocyte Microparticle Analysis to Detect Homologous/Autologous Blood Doping- a Transfusion Study

TypeinterventionalSponsorHamad Medical CorporationRan2018 to 2021Enrolled12ConditionsBlood Disease, Blood Transfusion, Autologous, Blood Doping, Blood Transfusion, HomologousArmsHomologous Blood Transfusion, Autologous Blood Transfusion
3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Weiyi NiDepartment of Molecular Genetics and Microbiology, College of Medicine, University of Florida, Gainesville, Florida, USA.
Caroline Le Guiner
Philippe Moullier
Richard O Snyder

Funding

UF Clinical and Translational Science AwardUL1TR000064 · NCATS · UNIVERSITY OF FLORIDA · PI NELSON, DAVID R · 2012 to 2014
$12.2M
NCATS NIH HHS UL1 TR000064
6 · The paper itself

Abstract

Sensitive and specific tests for detecting exogenous DNA molecules are useful for infectious disease diagnosis, gene therapy clinical trial safety, and gene doping surveillance. Taqman real-time PCR using specific sequence probes provides an effective approach to accurately and quantitatively detect exogenous DNA. However, one of the major challenges in these analyses is to eliminate false positive signals caused by either non-targeted exogenous or endogenous DNA sequences, or false negative signals caused by impurities that inhibit PCR. Although multiplex Taqman PCR assays have been applied to address these problems by adding extra primer-probe sets targeted to endogenous DNA sequences, the differences between targets can lead to different detection efficiencies. To avoid these complications, a Taqman PCR-based approach that incorporates an internal threshold control (ITC) has been developed. In this single reaction format, the target sequence and ITC template are co-amplified by the same primers, but are detected by different probes each with a unique fluorescent dye. Sample DNA, a prescribed number of ITC template molecules set near the limit of sensitivity, a single pair of primers, target probe and ITC probe are added to one reaction. Fluorescence emission signals are obtained simultaneously to determine the cycle thresholds (Ct) for amplification of the target and ITC sequences. The comparison of the target Ct with the ITC Ct indicates if a sample is a true positive for the target (i.e. Ct less than or equal to the ITC Ct) or negative (i.e. Ct greater than the ITC Ct). The utility of this approach was demonstrated in a nonhuman primate model of rAAV vector mediated gene doping in vivo and in human genomic DNA spiked with plasmid DNA.

Indexed as

AnimalsDNAGenetic VectorsHumansLeukocytes, MononuclearReal-Time Polymerase Chain ReactionReproducibility of ResultsSensitivity and SpecificityTransduction, GeneticDNA

Identifiers

PMID22570718
PMCPMC3343023

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.