Evidence map›Paper›PMID 22554484›Full record

ArticleMolecular imaging2012

Magnetic resonance imaging of ferumoxide-labeled mesenchymal stem cells in cartilage defects: in vitro and in vivo investigations.

Tobias D Henning, Rakhee Gawande, Aman Khurana, Sidhartha Tavri, Lydia Mandrussow, Daniel Golovko, Andrew Horvai, Barbara Sennino, Donald McDonald, Reinhard Meier and 4 more

Open access · greenAbstract read
In one paragraph

Article in Molecular imaging, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed
2.1field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 47 citations in OpenAlex.

  1. Review
  2. Article
  3. Multinuclear MRI in Drug Discovery.Molecules (Basel, Switzerland) · 2022
    Review
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. BioMed research international · 2018
    Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors at 1 institution in 1 country.

Tobias D HenningDepartment of Radiology, University of Cologne, Cologne, Germany.
Rakhee Gawande
Aman Khurana
Sidhartha Tavri
Lydia Mandrussow
Daniel Golovko
Andrew Horvai
Barbara Sennino
Donald McDonald
Reinhard Meier
Michael Wendland
Nikita Derugin
Thomas M Link
Heike E Daldrup-Link
University of Cologne · DE

Funding

Monitoring of Stem Cell Engraftment in Arthritic Joints with MR ImagingR01AR054458 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI DALDRUP-LINK, HEIKE ELIZABETH · 2008 to 2021
$6.7M
NIAMS NIH HHS R01 AR054458NIAMS NIH HHS R01AR054458
6 · The paper itself

Abstract

The purpose of this study was to (1) compare three different techniques for ferumoxide labeling of mesenchymal stem cells (MSCs), (2) evaluate if ferumoxide labeling allows in vivo tracking of matrix-associated stem cell implants (MASIs) in an animal model, and (3) compare the magnetic resonance imaging (MRI) characteristics of ferumoxide-labeled viable and apoptotic MSCs. MSCs labeled with ferumoxide by simple incubation, protamine transfection, or Lipofectin transfection were evaluated with MRI and histopathology. Ferumoxide-labeled and unlabeled viable and apoptotic MSCs in osteochondral defects of rat knee joints were evaluated over 12 weeks with MRI. Signal to noise ratios (SNRs) of viable and apoptotic labeled MASIs were tested for significant differences using t-tests. A simple incubation labeling protocol demonstrated the best compromise between significant magnetic resonance signal effects and preserved cell viability and potential for immediate clinical translation. Labeled viable and apoptotic MASIs did not show significant differences in SNR. Labeled viable but not apoptotic MSCs demonstrated an increasing area of T2 signal loss over time, which correlated to stem cell proliferation at the transplantation site. Histopathology confirmed successful engraftment of viable MSCs. The engraftment of iron oxide-labeled MASIs by simple incubation can be monitored over several weeks with MRI. Viable and apoptotic MASIs can be distinguished via imaging signs of cell proliferation at the transplantation site.

Indexed as

AnimalsCartilageCells, CulturedDextransFemaleIn Vitro TechniquesMagnetic Resonance ImagingMagnetite NanoparticlesMesenchymal Stem CellsMicroscopy, ElectronMicroscopy, FluorescenceRatsSwineDextransferumoxidesMagnetite Nanoparticles

Identifiers

PMID22554484
PMCPMC3727234
OpenAlexW2145568471

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.