Evidence map›Paper›PMID 22534738›Full record

ArticleSurgical endoscopy2012

Robot-assisted transvaginal peritoneoscopy using confocal endomicroscopy: a feasibility study in a porcine model.

Richard C Newton, David P Noonan, Valentina Vitiello, James Clark, Christopher J Payne, Jianzhong Shang, Mikael Sodergren, Ara Darzi, Guang-Zhong Yang

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
3.5field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 27 citations in OpenAlex.

  1. A Novel Semi-Autonomous Control Framework for Retina Confocal Endomicroscopy Scanning.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2019
    Article
  2. Article
  3. Article
  4. Article
  5. Force adaptive robotically assisted endomicroscopy for intraoperative tumour identification.International journal of computer assisted radiology and surgery · 2015
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Richard C NewtonDepartment of Surgery and Cancer, Imperial College London, St. Mary's Hospital, Praed Street, London, W2 1NY, UK. richardnewton22@yahoo.co.uk
David P Noonan
Valentina Vitiello
James Clark
Christopher J Payne
Jianzhong Shang
Mikael Sodergren
Ara Darzi
Guang-Zhong Yang
Imperial College London · GBSt. Mary's Hospital · GBSt Mary's Hospital · GB

Funding

Wellcome Trust GR083689
6 · The paper itself

Abstract

backgroundOptical biopsy methods such as probe-based confocal laser endomicroscopy (pCLE) provide useful intraoperative real-time information, especially during minimally invasive surgery with flexible endoscopic or robotic platforms. By translating the probe at constant pressure across the target tissue, undistorted "mosaics" can be produced. However, this poses ergonomic challenges with a conventional flexible endoscope.

methodsA 100 μm confocal depth pCLE probe was integrated into a previously described seven degrees-of-freedom articulated endoscopic robot. After estimating the average workspace created by a female pneumoperitoneum, the accessibility of the peritoneal cavity by the device for robot-assisted pCLE peritoneoscopy was calculated. To demonstrate its in vivo feasibility, the robot was inserted transvaginally in a pig, under laparoscopic vision. Optical biopsy was performed of several targets within the peritoneal cavity.

resultsThe workspace analysis calculated that 88 % of the surface of an estimated average female pneumoperitoneum could be contacted by the probe using the robot transvaginally. In vivo, the robot was manoeuvred to provide views of all abdominal and pelvic organs. At each target there was robotic acquisition of still pCLE images, and slowly translating images for the construction of increased field-of-view mosaics up to 2 mm in length. Optical biopsies took 1-2 min per target, and at 3.5 μm lateral resolution, the mosaic images showed characteristic features of anterior abdominal wall, liver, and spleen.

conclusionIn the porcine model, the robotically actuated method of performing peritoneoscopy and pCLE mosaicked optical biopsy is safe and provides a consistent means of acquiring near-histological grade images of submesothelial tissue. Clinical translation is likely to provide sufficient accessibility of the peritoneal cavity.

Indexed as

Microscopy, ConfocalRoboticsAnimalsEquipment DesignFeasibility StudiesFemaleLaparoscopesLaparoscopyModels, AnimalSwineVagina

Identifiers

PMID22534738
OpenAlexW2005275267

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.