Evidence map›Paper›PMID 22527416›Full record

Trial reportKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2013

Accuracy of manual instrumentation of tibial cutting guide in total knee arthroplasty.

R Iorio, G Bolle, F Conteduca, L Valeo, J Conteduca, D Mazza, A Ferretti

Abstract readClinical Trial
PubMed Publisher
In one paragraph

Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Surgical accuracy in high tibial osteotomy: coronal equivalence of computer navigation and gap measurement.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2016
    Trial
  4. Trial
  5. Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2013
    Trial
  6. Article
  7. Article
  8. Article
  9. Case-related factors affecting cutting errors of the proximal tibia in total knee arthroplasty assessed by computer navigation.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2018
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Accuracy of the second metatarsal as a landmark for the extramedullary tibial cutting guide in total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2014
    Article
  15. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

R IorioOrthopaedic Unit and "Kirk Kilgour" Sports Injury Centre, S. Andrea Hospital, University of Rome "Sapienza", Via Grottarossa, 1035, Rome (RM), Italy.
G Bolle
F Conteduca
L Valeo
J Conteduca
D Mazza
A Ferretti

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this study was to evaluate the accuracy of conventional instrumentation for tibial resection in total knee arthroplasty (TKA) as assessed by a computer-based navigation system during each phase of the surgical procedure. The hypothesis is that conventional instrumentation fails to achieve optimal accuracy in final implant positioning, thus leading to surgical errors.

methodsForty primary TKAs were performed. The resection guide was placed using an extramedullary guide. Accurate guide positioning was assessed by the navigation system prior to the osteotomy. The alignment measurement was repeated after resection and after component implantation in order to quantify the deviation caused by the manual positioning of the prosthetic components. A deviation ≥2° was considered unsatisfactory.

resultsIn the frontal plane, unsatisfactory results observed were as follows: 15 % with reference to manual positioning of the resection guide and 10 % with reference to definition of the resection plane with a tendency towards varus malalignment. In the sagittal plane, unsatisfactory results were as follows: 45 % with reference to manual positioning of the resection guide and 40 % with reference to definition of the resection plane with a trend of decreased tibial slope angle. The deviation between bone resection and subsequent implant placement was ≥2° in none of the cases.

conclusionsThe study confirms the hypothesis that conventional instrumentation fails to achieve optimal accuracy in the positioning of the tibial component. During each phase of the surgical procedure, a tendency towards varus malalignment and a decreased tibial slope angle were observed. LEVELS OF EVIDENCE: II.

Indexed as

AgedAged, 80 and overAnatomic LandmarksArthroplasty, Replacement, KneeBone MalalignmentHumansKnee ProsthesisMedical ErrorsOsteoarthritis, KneePostoperative ComplicationsSurgery, Computer-AssistedTibiaTreatment Outcome

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked