Multishot versus single-shot pulse sequences in very high field fMRI: a comparison using retinotopic mapping.

Jascha D Swisher, John A Sexton, J Christopher Gatenby, John C Gore, Frank Tong

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 22 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Resolving the Spatial Profile of Figure Enhancement in Human V1 through Population Receptive Field Modeling.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2020
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Jascha D SwisherDepartment of Psychology and Vision Research Center, Vanderbilt University, Nashville, Tennessee, United States of America. j.swisher@vanderbilt.edu
John A Sexton
J Christopher Gatenby
John C Gore
Frank Tong
Vanderbilt University · US

Funding

Integrated Imaging of Brain Function at 7 TeslaR01EB000461 · NIBIB · VANDERBILT UNIVERSITY · PI GORE, JOHN C · 2002 to 2012
$9.4M
Neural Representation of Features in the Human Visual CortexR01EY017082 · NEI · VANDERBILT UNIVERSITY · PI TONG, FRANK · 2007 to 2011
$2.1M
Spatial Scales of Functional Organization in Human Visual CortexF32EY019448 · NEI · VANDERBILT UNIVERSITY · PI SWISHER, JASCHA DROLL · 2009 to 2011
$136k
NEI NIH HHS F32 EY019448NEI NIH HHS R01 EY017082NIBIB NIH HHS 2R01 EB000461NIBIB NIH HHS R01 EB000461
6 · The paper itself

Abstract

High-resolution functional MRI is a leading application for very high field (7 Tesla) human MR imaging. Though higher field strengths promise improvements in signal-to-noise ratios (SNR) and BOLD contrast relative to fMRI at 3 Tesla, these benefits may be partially offset by accompanying increases in geometric distortion and other off-resonance effects. Such effects may be especially pronounced with the single-shot EPI pulse sequences typically used for fMRI at standard field strengths. As an alternative, one might consider multishot pulse sequences, which may lead to somewhat lower temporal SNR than standard EPI, but which are also often substantially less susceptible to off-resonance effects. Here we consider retinotopic mapping of human visual cortex as a practical test case by which to compare examples of these sequence types for high-resolution fMRI at 7 Tesla. We performed polar angle retinotopic mapping at each of 3 isotropic resolutions (2.0, 1.7, and 1.1 mm) using both accelerated single-shot 2D EPI and accelerated multishot 3D gradient-echo pulse sequences. We found that single-shot EPI indeed led to greater temporal SNR and contrast-to-noise ratios (CNR) than the multishot sequences. However, additional distortion correction in postprocessing was required in order to fully realize these advantages, particularly at higher resolutions. The retinotopic maps produced by both sequence types were qualitatively comparable, and showed equivalent test/retest reliability. Thus, when surface-based analyses are planned, or in other circumstances where geometric distortion is of particular concern, multishot pulse sequences could provide a viable alternative to single-shot EPI.