ArticleJournal of vascular surgery2012
Two-wavelength near-infrared fluorescence for the quantitation of drug antiplatelet effects in large animal model systems.
Article in Journal of vascular surgery, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 22 citations in OpenAlex.
- Ultrasound-responsive theranostic platform for the timely monitoring and efficient thrombolysis in thrombi of tPA resistance.Nature communications · 2024Article
- Real-Time Fluorescence Imaging in Thoracic Surgery.The Korean journal of thoracic and cardiovascular surgery · 2019Article
- Endocrine-specific NIR fluorophores for adrenal gland targeting.Chemical communications (Cambridge, England) · 2016Article
- Near-Infrared Illumination of Native Tissues for Image-Guided Surgery.Journal of medicinal chemistry · 2016Article
- Cartilage-Specific Near-Infrared Fluorophores for Biomedical Imaging.Angewandte Chemie (International ed. in English) · 2015Article
- Near-infrared imaging for the assessment of anastomotic patency, thrombosis, and reperfusion in microsurgery: a pilot study in a porcine model.Microsurgery · 2015Article
- Structure-inherent targeting of near-infrared fluorophores for parathyroid and thyroid gland imaging.Nature medicine · 2015Article
- Phosphonated near-infrared fluorophores for biomedical imaging of bone.Angewandte Chemie (International ed. in English) · 2014Article
- Prototype nerve-specific near-infrared fluorophores.Theranostics · 2014Article
- Simultaneous mapping of pan and sentinel lymph nodes for real-time image-guided surgery.Theranostics · 2014Article
- Highly charged cyanine fluorophores for trafficking scaffold degradation.Biomedical materials (Bristol, England) · 2013Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 4 countries.
Funding
Abstract
objectiveIntraoperative imaging of intravascular thrombi is limited by the inability of visible light to penetrate thick-walled vessels. Near-infrared (NIR) light has relatively high tissue penetration and low autofluorescence and scatter, offering significant advantages. We hypothesized that the development of 700-nm NIR fluorophores for platelet labeling, in conjunction with existing 800-nm NIR fluorophores, would permit simultaneous and separable quantitation of intravascular thrombi and measurement of the antiplatelet effect of drugs.
methodsWe synthesized a series of lipophilic, cationic, polymethine indocyanine dyes (MHI-86, 94, 106, and 114) that emit at approximately 700 nm. Platelet uptake was optimized in vitro and the bioactivity and blood half-life of labeled platelets was characterized in vitro and in vivo. FeCl(3)-induced injury of the femoral arteries and intravascular thrombus formation was performed in 35-kg Yorkshire pigs. A combination of 700-nm and 800-nm NIR fluorophore-labeled platelets was used in conjunction with the fluorescence-assisted resection and exploration imaging system to image and quantify the antiplatelet effect of cilostazol and acetylsalicylic acid.
resultsMHI-114 was incorporated at nearly 4.1 × 10(6) molecules per platelet without affecting platelet function. When infused into pigs, the signal-to-background ratio of MHI-114-labeled platelets exhibited a blood half-life of 16.4 ± 2.2 (mean ± SEM; n = 3) minute and generated a signal-to-background ratio of 2.5 ± 0.5 (mean ± SEM; n = 3) at the site of thrombi. Using dual-NIR-labeled platelet populations, cilostazol and acetylsalicylic acid were found to cause a reduction in platelet incorporation into thrombi of 51 ± 2% and 10 ± 1% (mean ± SEM; n = 3), respectively, relative to vehicle-only treated control thrombi.
conclusionsNew platelet-avid 700-nm NIR fluorophores permit simultaneous two-wavelength NIR fluorescence imaging and quantitation of intravascular thrombi in intact vessels approaching the size of humans and can be used to study the antiplatelet effect of drugs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.