Evidence map›Paper›PMID 22476531›Full record

ArticleLasers in medical science2013

The influence of Nd:YAG laser irradiation on Fluoroptic® temperature measurement: an experimental evaluation.

Frank Hübner, Babak Bazrafshan, Jörg Roland, Antje Kickhefel, Thomas Josef Vogl

Abstract readEvaluation Study
PubMed Publisher
In one paragraph

Article in Lasers in medical science, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Article
  6. Image-guided thermal ablation with MR-based thermometry.Quantitative imaging in medicine and surgery · 2017
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Frank HübnerInstitute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe University, Frankfurt am Main, Germany. frank.huebner@kgu.de
Babak Bazrafshan
Jörg Roland
Antje Kickhefel
Thomas Josef Vogl
Goethe University Frankfurt · DESiemens Healthcare (Germany) · DEGoethe Institute · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study was to experimentally evaluate temperature monitoring with a Fluoroptic® temperature probe in the presence of laser irradiation from a Nd:YAG laser, which is mainly used for clinical MR-guided laser-induced interstitial thermotherapy. Temperature measurements were performed using a Fluoroptic® probe in comparison to a thermocouple probe in a gel phantom and an ex vivo pig liver at distances of 6.5 to 14 mm to the laser applicator (laser energy of 30.8 W). To evaluate the artifacts in the temperature measurement, the laser was turned on and off three times during the entire experiment. A comparison of the fiber-optic measurements with MR thermometry was also performed in pig liver by means of the proton resonance frequency method at a distance of 6 mm. Depending on the distance, the temperature measured by the fiber-optic probe deviated from the thermocouple probe temperature. The phantom deviations of 0.4 to 34.3 % were observed. The differences in the liver were smaller and ranged from 1.6 to 5.2 %. The Bland-Altman mean of differences between MR and fiber-optic temperature measurements was 0.02 °C and the 95 % limits of agreement value was ± 2.25°C. During laser application, considerable artifacts occurred in the Fluoroptic® measurements in short distances which was induced by laser energy absorption by the probe coating. No artifacts were verifiable at a distance of 14 mm in both mediums. The good conformity with MR thermometry resulted from the shorter turn-on times of the laser since the laser irradiation had only a minor effect on the measurements.

Indexed as

Lasers, Solid-StateAnimalsArtifactsBody TemperatureFiber Optic TechnologyLiverPhantoms, ImagingSwineThermography

Identifiers

PMID22476531
OpenAlexW2010918211

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.