Evidence map›Paper›PMID 22402808›Full record

ArticleClinical orthopaedics and related research2012

High 10-year survival rate with an anatomic cementless stem (SPS).

Elhadi Sariali, Alexandre Mouttet, Philippe Mordasini, Yves Catonné

Abstract read
In one paragraph

Article in Clinical orthopaedics and related research, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Promising medium-term results of anterior approach with an anatomical short stem in primary hip arthroplasty.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2021
    Article
  5. Article
  6. Article
  7. Article
  8. CORR InsightsClinical orthopaedics and related research · 2017
    Article
  9. Article
  10. Short uncemented stems allow greater femoral flexibility and may reduce peri-prosthetic fracture risk: a dry bone and cadaveric study.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2015
    Article
  11. Cementless hydroxyapatite coated hip prostheses.BioMed research international · 2015
    Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Elhadi SarialiDepartment of Orthopaedic Surgery, Hôpital Pitié Salpétrière, 47-83 Bd de l'Hôpital, 75013, Paris, France. hedisari@yahoo.fr
Alexandre Mouttet
Philippe Mordasini
Yves Catonné

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundProximal cementless fixation using anatomic stems reportedly increases femoral fit and avoids stress-shielding. However, thigh pain was reported with the early stem designs. Therefore, a new anatomic cementless stem design was based on an average three-dimensional metaphyseal femoral shape. However, it is unclear whether this stem reduces the incidence of thigh pain. QUESTIONS/PURPOSES: We asked whether this stem design was associated with a low incidence of thigh pain and provided durable fixation and high function.

methodsOne hundred seventy-one patients (176 THAs) who had the anatomic proximal hydroxyapatite-coated stem implanted were reviewed. Eleven (6%) patients were lost to followup and 34 (20%) died without revision surgery. We used the Harris hip score (HHS) to assess pain and function. We evaluated femoral stem fixation and stability with the score of Engh et al. and also calculated a 10-year survival analysis. We assessed 126 patients (131 hips) at a mean followup of 10 years (range, 8-11 years)

resultsAt last followup, two patients described slight thigh pain that did not limit their physical activities. All stems appeared radiographically stable and one stem was graded nonintegrated but stable. Five patients had revision surgery: one on the femoral side (for posttraumatic fracture) and four on the acetabular side. Considering stem revision for aseptic loosening as the end point, survivorship was 100% (range, 95.4%-99.9%) at 10 years.

conclusionThis anatomic cementless design using only metaphyseal fixation with a wide mediolateral flare, a sagittal curvature, and torsion, allowed durable proximal stem stability and fixation.

Indexed as

Hip ProsthesisAdultAgedAged, 80 and overArthroplasty, Replacement, HipBiomechanical PhenomenaCeramicsCoated Materials, BiocompatibleDurapatiteFemaleHip JointHumansKaplan-Meier EstimateMaleMiddle AgedMultivariate AnalysisCoated Materials, BiocompatibleDurapatitePolyethylenesultra-high molecular weight polyethyleneZirconiumzirconium oxide

Identifiers

PMID22402808
PMCPMC3369068

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.