Trial reportClinical research in cardiology : official journal of the German Cardiac Society2012
AV interval optimization using pressure volume loops in dual chamber pacemaker patients with maintained systolic left ventricular function.
Trial report in Clinical research in cardiology : official journal of the German Cardiac Society, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Impact of left ventricular conduction defect with or without need for permanent right ventricular pacing on functional and clinical recovery after TAVR.Clinical research in cardiology : official journal of the German Cardiac Society · 2015Trial
- Not left ventricular lead position, but the extent of immediate asynchrony reduction predicts long-term response to cardiac resynchronization therapy.Clinical research in cardiology : official journal of the German Cardiac Society · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAtrioventricular (AV) interval optimization is often deemed too time-consuming in dual-chamber pacemaker patients with maintained LV function. Thus the majority of patients are left at their default AV interval.
objectiveTo quantify the magnitude of hemodynamic improvement following AV interval optimization in chronically paced dual chamber pacemaker patients. PATIENTS AND
methodsA pressure volume catheter was placed in the left ventricle of 19 patients with chronic dual chamber pacing and an ejection fraction >45 % undergoing elective coronary angiography. AV interval was varied in 10 ms steps from 80 to 300 ms, and pressure volume loops were recorded during breath hold.
resultsThe average optimal AV interval was 152 ± 39 ms compared to 155 ± 8 ms for the average default AV interval (range 100-240 ms). The average improvement in stroke work following AV interval optimization was 935 ± 760 mmHg/ml (range 0-2,908; p < 0.001), which translates into an average improvement of 14 ± 9 % (range 0-28). A 10 ms variation of the AV interval changes the average stroke work by 207 ± 162 mmHg/ml. AV interval optimization also leads to improved systolic dyssynchrony indices (17.7 ± 7.0 vs. 19.4 ± 7.1 %; p = 0.01).
conclusionThe overall hemodynamic effect of AV interval optimization in patients with maintained LV function is in the same range as for patients undergoing cardiac resynchronization therapy for several parameters. The positive effect of AV interval optimization also applies to patients who have been chronically paced for years.
Indexed as