Evidence map›Paper›PMID 22401145›Full record

ArticleAnalytical chemistry2012

Improved mass defect model for theoretical tryptic peptides.

Indranil Mitra, Alexey V Nefedov, Allan R Brasier, Rovshan G Sadygov

Open access · greenAbstract read
In one paragraph

Article in Analytical chemistry, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.0field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Advanced Multidimensional Separations in Mass Spectrometry: Navigating the Big Data Deluge.Annual review of analytical chemistry (Palo Alto, Calif.) · 2016
    Article
  3. Using SEQUEST with theoretically complete sequence databases.Journal of the American Society for Mass Spectrometry · 2015
    Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Indranil MitraDepartment of Biochemistry and Molecular Biology, The University of Texas Medical Branch, Galveston, Texas 77555, United States.
Alexey V Nefedov
Allan R Brasier
Rovshan G Sadygov
The University of Texas Medical Branch at Galveston · US

Funding

UTMB CLINICAL AND TRANSLATIONAL SCIENCE AWARD: NASA BED REST STUDIESUL1RR029876 · NCRR · UNIVERSITY OF TEXAS MED BR GALVESTON · PI BRASIER, ALLAN R. · 2009 to 2011
$17.7M
UTMB Clinical and Translational Science AwardUL1TR000071 · NCATS · UNIVERSITY OF TEXAS MED BR GALVESTON · PI BRASIER, ALLAN R. · 2012 to 2014
$14.4M
NCATS NIH HHS UL1 TR000071NCRR NIH HHS UL1 RR029876NCRR NIH HHS UL1RR029876NHLBI NIH HHS HHSN268201000037CNIAID NIH HHS HHSN272200800048C
6 · The paper itself

Abstract

Improvements in the mass accuracy and resolution of mass spectrometers have greatly aided mass spectrometry-based proteomics in profiling complex biological mixtures. With the use of innovative bioinformatics approaches, high mass accuracy and resolution information can be used for filtering chemical noise in mass spectral data. Using our recent algorithmic developments, we have generated the mass distributions of all theoretical tryptic peptides composed of 20 natural amino acids and with masses limited to 3.5 kDa. Peptide masses are distributed discretely, with well-defined peak clusters separated by empty or sparsely populated trough regions. Accurate models for peak centers and widths can be used to filter peptide signals from chemical noise. We modeled mass defects, the difference between monoisotopic and nominal masses, and peak centers and widths in the peptide mass distributions. We found that peak widths encompassing 95% of all peptide sequences are substantially smaller than previously thought. The result has implications for filtering out larger stretches of the mass axis. Mass defects of peptides exhibit an oscillatory behavior which is damped at high mass values. The periodicity of the oscillations is about 14 Da which is the most common difference between the masses of the 20 natural amino acids. To determine the effects of amino acid modifications on our findings, we examined the mass distributions of peptides composed of the 20 natural amino acids, oxidized Met, and phosphorylated Ser, Thr, and Tyr. We found that extension of the amino acid set by modifications increases the 95% peak width. Mass defects decrease, reflecting the fact that the average mass defect of natural amino acids is larger than that of oxidized Met. We propose that a new model for mass defects and peak widths of peptides may improve peptide identifications by filtering chemical noise in mass spectral data.

Indexed as

AlgorithmsAmino AcidsMass SpectrometryModels, ChemicalPeptidesTrypsinAmino AcidsPeptidesTrypsin

Identifiers

PMID22401145
PMCPMC3312599
OpenAlexW2058406408

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.