Trial reportJournal of visualized experiments : JoVE2012
The WATCHMAN left atrial appendage closure device for atrial fibrillation.
Trial report in Journal of visualized experiments : JoVE, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 48 citations in OpenAlex.
- Anti-amyloid treatment in Alzheimer disease: updated implications for patients with cerebral amyloid angiopathy and other cerebrovascular conditions.Frontiers in neurology · 2026Review
- Review
- Left atrial appendage closure versus anticoagulation in the management of atrial fibrillation: a systematic review, meta-analysis, and meta-regression analysis.Annals of medicine and surgery (2012) · 2025Article
- Cerebrovascular Management Considerations in Patients on AATs.Journal of clinical medicine · 2025Review
- Anesthetic Choice for Percutaneous Transcatheter Closure of the Left Atrial Appendage: A National Anesthesia Clinical Outcomes Registry Analysis.Annals of cardiac anaesthesia · 2024Article
- Percutaneous left atrial appendage closure with the Watchman device: a systematic review.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2024Review
- Left atrial appendage closure in patients with reversed chicken-wing morphology: Anatomical features and procedural strategy.Heliyon · 2023Article
- A Novel Echocardiographic-Based Classification for the Prediction of Peri-Device Leakage following Left Atrial Appendage Occluder Implantation.Journal of clinical medicine · 2022Article
- Left atrial appendage exclusion in atrial fibrillation.Frontiers in cardiovascular medicine · 2022Review
- Left atrial appendage size in patients with atrial fibrillation in Japan and the United States.Heart and vessels · 2021Article
- Left atrial appendage closure using the Watchman device in patients with off-label anatomy: "No man left behind".Cardiology journal · 2020Article
- Role of real time-three dimensional transesophageal echocardiography in left atrial appendage closure with LACBESExperimental and therapeutic medicine · 2019Article
- The Efficacy and Safety of the WATCHMAN Device in LAA Occlusion in Patients with Non-Valvular Atrial Fibrillation Contraindicated to Oral Anticoagulation: A Focused Review.Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia · 2018Review
- Accuracy of Commonly-Used Imaging Modalities in Assessing Left Atrial Appendage for Interventional Closure: Review Article.Journal of clinical medicine · 2018Review
- Feasibility of intracardiac echocardiography imaging from the left superior pulmonary vein for left atrial appendage occlusion.The international journal of cardiovascular imaging · 2018Article
- 3D-computed tomography to compare the dimensions of the left atrial appendage in patients with normal sinus rhythm and those with paroxysmal atrial fibrillation.Heart and vessels · 2018Article
- Left atrial appendage exclusion-Where do we stand?Journal of thoracic disease · 2014Review
- Catheter ablation in combination with left atrial appendage closure for atrial fibrillation.Journal of visualized experiments : JoVE · 2013Article
- Improvement in Left Atrial Strain among Patients Undergoing Percutaneous Left Atrial Appendage Closure.Journal of cardiovascular echographyArticle
- Role of transesophageal echocardiography during left atrial appendage occlusion device closure in a patient with non-valvular atrial fibrillation and angiodysplasia of the colon.Annals of cardiac anaesthesiaArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Atrial fibrillation (AF) is the most common cardiac arrhythmia, affecting an estimated 6 million people in the United States (1). Since AF affects primarily elderly people, its prevalence increases parallel with age. As such, it is expected that 15.9 million Americans will be affected by the year 2050 (2). Ischemic stroke occurs in 5% of non-anticoagulated AF patients each year. Current treatments for AF include rate control, rhythm control and prevention of stroke (3). The American College of Cardiology, American Heart Association, and European Society of Cardiology currently recommended rate control as the first course of therapy for AF (3). Rate control is achieved by administration of pharmacological agents, such as β-blockers, that lower the heart rate until it reaches a less symptomatic state (3). Rhythm control aims to return the heart to its normal sinus rhythm and is typically achieved through administration of antiarrhythmic drugs such as amiodarone, electrical cardioversion or ablation therapy. Rhythm control methods, however, have not been demonstrated to be superior to rate-control methods (4-6). In fact, certain antiarrhythmic drugs have been shown to be associated with higher hospitalization rates, serious adverse effects (3), or even increases in mortality in patients with structural heart defects (7). Thus, treatment with antiarrhythmics is more often used when rate-control drugs are ineffective or contraindicated. Rate-control and antiarrhythmic agents relieve the symptoms of AF, including palpitations, shortness of breath, and fatigue (8), but don't reliably prevent thromboembolic events (6). Treatment with the anticoagulant drug warfarin significantly reduces the rate of stroke or embolism (9,10). However, because of problems associated with its use, fewer than 50% of patients are treated with it. The therapeutic dose is affected by drug, dietary, and metabolic interactions, and thus requires detailed monitoring. In addition, warfarin has the potential to cause severe, sometimes lethal, bleeding (2). As an alternative, aspirin is commonly prescribed. While aspirin is typically well tolerated, it is far less effective at preventing stroke (10). Other alternatives to warfarin, such as dabigatran (11) or rivaroxaban (12) demonstrate non-inferiority to warfarin with respect to thromboembolic events (in fact, dabigatran given as a high dose of 150 mg twice a day has shown superiority). While these drugs have the advantage of eliminating dietary concerns and eliminating the need for regular blood monitoring, major bleeding and associated complications, while somewhat less so than with warfarin, remain an issue (13-15). Since 90% of AF-associated strokes result from emboli that arise from the left atrial appendage (LAA) (2), one alternative approach to warfarin therapy has been to exclude the LAA using an implanted device to trap blood clots before they exit. Here, we demonstrate a procedure for implanting the WATCHMAN Left Atrial Appendage Closure Device. A transseptal cannula is inserted through the femoral vein, and under fluoroscopic guidance, inter-atrial septum is crossed. Once access to the left atrium has been achieved, a guidewire is placed in the upper pulmonary vein and the WATCHMAN Access Sheath and dilator are advanced over the wire into the left atrium. The guidewire is removed, and the access sheath is carefully advanced into the distal portion of the LAA over a pigtail catheter. The WATCHMAN Delivery System is prepped, inserted into the access sheath, and slowly advanced. The WATCHMAN device is then deployed into the LAA. The device release criteria are confirmed via fluoroscopy and transesophageal echocardiography (TEE) and the device is released.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.