Evidence map›Paper›PMID 22395119›Full record

ArticleASAIO journal (American Society for Artificial Internal Organs : 1992)

Thromboresistance characterization of extruded nitric oxide-releasing silicone catheters.

Kagya A Amoako, Christopher Archangeli, Hitesh Handa, Terry Major, Mark E Meyerhoff, Gail M Annich, Robert H Bartlett

Abstract read
In one paragraph

Article in ASAIO journal (American Society for Artificial Internal Organs : 1992). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Platelet Transfusion Practice and Related Outcomes in Pediatric Extracorporeal Membrane Oxygenation.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2020
    Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Kagya A AmoakoDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, 48109-0686, USA.
Christopher Archangeli
Hitesh Handa
Terry Major
Mark E Meyerhoff
Gail M Annich
Robert H Bartlett
University of Michigan–Ann Arbor · US

Funding

Pediatric Implantable Artificial LungR01HD015434 · NICHD · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI HIRSCHL, RONALD BRUCE · 1985 to 2021
$10.8M
Development of a Total Artificial LungR01HL069420 · NHLBI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI BARTLETT, ROBERT H. · 2002 to 2011
$10.1M
Biocompatible Chemical Sensors Via Nitric Oxide Release/GenerationR01EB000783 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI MEYERHOFF, MARK E · 2002 to 2013
$3.1M
NHLBI NIH HHS 2R01 HL069420-06NHLBI NIH HHS R01 HL069420NIBIB NIH HHS EB-000783NIBIB NIH HHS R01 EB000783NICHD NIH HHS R01 HD01534NICHD NIH HHS R01 HD015434
6 · The paper itself

Abstract

Intravascular catheters used in clinical practice can activate platelets, leading to thrombus formation and stagnation of blood flow. Nitric oxide (NO)-releasing polymers have been shown previously to reduce clot formation on a number of blood contacting devices. In this work, trilaminar NO-releasing silicone catheters were fabricated and tested for their thrombogenicity. All catheters had specifications of L = 6 cm, inner diameter = 21 gauge (0.0723 cm), outer diameter = 12 gauge (0.2052 cm), and NO-releasing layer thickness = 200 ± 11 µm. Control and NO-releasing catheters were characterized in vitro for their NO flux and NO release duration by gas phase chemiluminescence measurements. The catheters were then implanted in the right and left internal jugular veins of (N = 6 and average weight = 3 kg) adult male rabbits for 4 hours thrombogenicity testing. Platelet counts and function, methemoglobin (metHb), hemoglobin (Hb), and white cell counts and functional time (defined as patency time of catheter) were monitored as measured outcomes. Nitric oxide-releasing catheters (N = 6) maintained an average flux above (2 ± 0.5) × 10(-10) mol/min/cm for more than 24 hours, whereas controls showed no NO release. Methemoglobin, Hb, white cell, and platelet counts and platelet function at 4 hours were not significantly different from baseline (α = 0.05). However, clots on controls were visibly larger and prevented blood draws at a significantly (p < 0.05) earlier time (2.3 ± 0.7 hours) into the experiment, whereas all NO-releasing catheters survived the entire 4 hours test period. Results indicate that catheter NO flux levels attenuated thrombus formation in a short-term animal model.

Indexed as

AnimalsCathetersLuminescent MeasurementsMaleNitric Oxide DonorsPlatelet CountRabbitsSilicone ElastomersThrombosisExtrudeNitric Oxide DonorsSilicone Elastomers

Identifiers

PMID22395119
PMCPMC3805133
OpenAlexW2053730256

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.