ArticleJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2012
Long-term results of a cardiovascular implantable electronic device wrapped with an expanded polytetrafluoroethylene sheet.
Article in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 29 citations in OpenAlex.
- Implanting a gold-coated cardioverter-defibrillator as a solution to cardiac implantable device hypersensitivity: a case report.European heart journal. Case reports · 2025Article
- Angioedema presumably caused by hypersensitivity reactions to pacemaker implantation.Journal of cardiology cases · 2025Article
- Pulse-Generator Rejection of Probable Allergic Origin in Deep Brain Stimulation: A Rare Complication Successfully Managed with a Polytetrafluoroethylene-Covered Device.Movement disorders clinical practice · 2025Article
- A method for successfully implanting an implantable cardioverter-defibrillator wrapped with an expanded polytetrafluoroethylene sheet in a patient with metal allergy.Journal of cardiology cases · 2023Article
- Hypersensitivity Reactions to Components of Cardiac Implantable Electronic Devices and Their Treatment: A Systematic Review.Arrhythmia & electrophysiology review · 2023Review
- Photoactive fluoropolymer surfaces that release sensitizer drug molecules.The journal of physical chemistry. B · 2015Article
- Prevention of pacemaker-associated contact dermatitis by polytetrafluoroethylene sheet and conduit coating of the pacemaker system.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2014Article
- Biomaterials in cardiovascular research: applications and clinical implications.BioMed research international · 2014Review
- Systemic contact dermatitis and allergy to biomedical devices.Current allergy and asthma reports · 2013Review
- Journal of Artificial Organs 2012: the year in review.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2013Review
- Biomaterial applications in cardiovascular tissue repair and regeneration.Expert review of cardiovascular therapy · 2012Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The use of an expanded polytetrafluoroethylene (ePTFE) sheet wrapping device for patients with pacemaker contact dermatitis is still controversial. This study aimed to retrospectively investigate the occurrence rate of allergies and other complications after implantation of a cardiovascular implantable electronic device (CIED) wrapped with an ePTFE sheet. A total of 4,497 procedures of CIED implantation were performed at our institution between January 1993 and April 2010. Among 19 patients who underwent implantation of an electronic cardiac device wrapped with an ePTFE sheet, device implantation was performed in 11 patients for secondary prevention of device contact sensitivity, in 7 patients for primary prevention of device contact sensitivity, and in 1 patient for avoiding over-sensing of myopotentials. During follow-up periods (mean 46 ± 34 months), there were no allergic or inflammatory reactions to components of the device or ePTFE itself. Among 11 patients with a device wrapped with an ePTFE sheet for secondary prevention, 5 patients completed device replacement due to battery depletion and 3 patients had infections from the device. Wrapping implantable devices with an ePTFE sheet is an effective way of preventing device sensitivity in patients who require CIED therapy. However, the risk of infection from the device should be taken into consideration.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials