Evidence map›Paper›PMID 22357891›Full record

ArticleRadiology2012

Micro-MR imaging-based computational biomechanics demonstrates reduction in cortical and trabecular bone strength after renal transplantation.

Chamith S Rajapakse, Mary B Leonard, Yusuf A Bhagat, Wenli Sun, Jeremy F Magland, Felix W Wehrli

Abstract read
In one paragraph

Article in Radiology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 45 papers.

0numbers the graph read from it
0cells of the map it votes in
45citing papers in PubMed
6.8field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

45 citing papers in PubMed, 91 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Trial
  4. Corticosteroid, Parathyroid Hormone, and Body Composition Associations With Bone Density and Structure Following Kidney Transplantation.American journal of kidney diseases : the official journal of the National Kidney Foundation · 2026
    Article
  5. Review
  6. Review
  7. Article
  8. Review
  9. Review
  10. Clinical predictors of incipient vertebral fractures and bone mineral density in kidney transplant patients.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022
    Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Review
  16. Survey of MRI Usefulness for the Clinical Assessment of Bone Microstructure.International journal of molecular sciences · 2021
    Review
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Chamith S RajapakseDepartment of Radiology, University of Pennsylvania, 1 Founders, 3400 Spruce St, Philadelphia, PA 19104, USA. chamith@mail.med.upenn.edu
Mary B Leonard
Yusuf A Bhagat
Wenli Sun
Jeremy F Magland
Felix W Wehrli
Hospital of the University of Pennsylvania · USUniversity of Pennsylvania · USRadiological Society of North America · US

Funding

Osteoporosis Treatment Response Assessed by Micromechanical Modeling of MRI DataR01AR055647 · NIAMS · UNIVERSITY OF PENNSYLVANIA · PI WEHRLI, FELIX W · 2007 to 2016
$3.6M
CHANGES IN SKELETAL MICROARCHITECTURE FOLLOWING RENAL TRANSPLANTATIONR01DK075648 · NIDDK · CHILDREN'S HOSP OF PHILADELPHIA · PI LEONARD, MARY BETH · 2007 to 2011
$2.5M
Training in Quantitative Magnetic Resonance ImagingT32EB000814 · NIBIB · UNIVERSITY OF PENNSYLVANIA · PI WEHRLI, FELIX W · 2003 to 2012
$1.7M
Patient Oriented Research in Vitamin D Deficiency in CKDK24DK076808 · NIDDK · STANFORD UNIVERSITY · PI LEONARD, MARY BETH · 2007 to 2016
$1.7M
Computational Biomechanics for Prediction of Osteoporotic Vertebral Fracture RiskK25AR060283 · NIAMS · UNIVERSITY OF PENNSYLVANIA · PI RAJAPAKSE, CHAMITH SUDESH · 2011 to 2014
$491k
NIAMS NIH HHS K25 AR 060283NIAMS NIH HHS K25 AR060283NIAMS NIH HHS R01 AR 055647NIAMS NIH HHS R01 AR055647NIBIB NIH HHS T32 EB 000814NIBIB NIH HHS T32 EB000814NIDDK NIH HHS K24 DK 076808NIDDK NIH HHS K24 DK076808NIDDK NIH HHS R01 DK 075648NIDDK NIH HHS R01 DK075648
6 · The paper itself

Abstract

purposeTo examine the ability of three-dimensional micro-magnetic resonance (MR) imaging-based computational biomechanics to detect mechanical alterations in trabecular bone and cortical bone in the distal tibia of incident renal transplant recipients 6 months after renal transplantation and compare them with bone mineral density (BMD) outcomes. MATERIALS AND

methodsThe study was approved by the institutional review board and complied with HIPAA guidelines. Written informed consent was obtained from all subjects. Micro-MR imaging of distal tibial metaphysis was performed within 2 weeks after renal transplantation (baseline) and 6 months later in 49 participants (24 female; median age, 44 years; range, 19-61 years) with a clinical 1.5-T whole-body imager using a modified three-dimensional fast large-angle spin-echo pulse sequence. Micro-finite-element models for cortical bone, trabecular bone, and whole-bone section were generated from each image by delineating the endosteal and periosteal boundaries. Mechanical parameters (stiffness and failure load) were estimated with simulated uniaxial compression tests on the micro-finite-element models. Structural parameters (trabecular bone volume fraction [BV/TV, bone volume to total volume ratio], trabecular thickness [TbTh], and cortical thickness [CtTh]) were computed from micro-MR images. Total hip and spine areal BMD were determined with dual-energy x-ray absorptiometry (DXA). Parameters obtained at the follow-up were compared with the baseline values by using parametric or nonparametric tests depending on the normality of data.

resultsAll mechanical parameters were significantly lower at 6 months compared with baseline. Decreases in cortical bone, trabecular bone, and whole-bone stiffness were 3.7% (P = .03), 4.9% (P = .03), and 4.3% (P = .003), respectively. Decreases in cortical bone, trabecular bone, and whole-bone failure strength were 7.6% (P = .0003), 6.0% (P = .004), and 5.6% (P = .0004), respectively. Conventional structural measures, BV/TV, TbTh, and CtTh, did not change significantly. Spine BMD decreased by 2.9% (P < .0001), while hip BMD did not change significantly at DXA.

conclusionMR imaging-based micro-finite-element analysis suggests that stiffness and failure strength of the distal tibia decrease over a 6-month interval after renal transplantation.

Indexed as

Kidney TransplantationAbsorptiometry, PhotonAdultBiomechanical PhenomenaBone DensityChronic Kidney Disease-Mineral and Bone DisorderFemaleFinite Element AnalysisHumansImage Interpretation, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingMaleMiddle AgedProspective StudiesTibia

Identifiers

PMID22357891
PMCPMC3285225
OpenAlexW2123897227

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.