ArticleThe Journal of the Acoustical Society of America2012
Relationships of quantitative ultrasound parameters with cancellous bone microstructure in human calcaneus in vitro.
Article in The Journal of the Acoustical Society of America, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed.
- Biomechanical structure-function relations for human trabecular bone - comparison of calcaneus, femoral neck, greater trochanter, proximal tibia, and vertebra.Computer methods in biomechanics and biomedical engineering · 2023Article
- Scattering in Cancellous Bone.Advances in experimental medicine and biology · 2022Article
- Ultrasonic Assessment of Cancellous Bone Based on the Two-Wave Phenomenon.Advances in experimental medicine and biology · 2022Article
- Estimation of Cadaveric Age by Ultrasonography.Diagnostics (Basel, Switzerland) · 2020Article
- Evaluation of Structural Anisotropy in a Porous Titanium Medium Mimicking Trabecular Bone Structure Using Mode-Converted Ultrasonic Scattering.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2020Article
- Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2020Review
- A Combined Ultrasonic Backscatter Parameter for Bone Status Evaluation in Neonates.Computational and mathematical methods in medicine · 2020Article
- Artificial neural network to estimate micro-architectural properties of cortical bone using ultrasonic attenuation: A 2-D numerical study.Computers in biology and medicine · 2019Article
- Predicting Structural Properties of Cortical Bone by Combining Ultrasonic Attenuation and an Artificial Neural Network (ANN): 2-D FDTD Study.Image Analysis and Recognition: International Conference, ICIAR ... : proceedings. ICIAR · 2019Article
- The effect of pore size and density on ultrasonic attenuation in porous structures with mono-disperse random pore distribution: A two-dimensional in-silico study.The Journal of the Acoustical Society of America · 2018Article
- Ultrasonic backscatter difference measurements of cancellous bone from the human femur: Relation to bone mineral density and microstructure.The Journal of the Acoustical Society of America · 2018Article
- A Cross-Sectional Study of the Association between Autoantibodies and Qualitative Ultrasound Index of Bone in an Elderly Sample without Clinical Autoimmune Disease.Journal of immunology research · 2018Article
- Microstructural characterization of trabecular bone using ultrasonic backscattering and diffusion parameters.The Journal of the Acoustical Society of America · 2017Article
- Correlation between the combination of apparent integrated backscatter-spectral centroid shift and bone mineral density.Journal of medical ultrasonics (2001) · 2016Article
- Effect of intervening tissues on ultrasonic backscatter measurements of bone: An in vitro study.The Journal of the Acoustical Society of America · 2015Article
- Calcaneal quantitative ultrasound as a determinant of bone health status: what properties of bone does it reflect?International journal of medical sciences · 2013Review
- New perspectives in echographic diagnosis of osteoporosis on hip and spine.Clinical cases in mineral and bone metabolism : the official journal of the Italian Society of Osteoporosis, Mineral Metabolism, and Skeletal DiseasesReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Ultrasound parameters (attenuation, phase velocity, and backscatter), bone mineral density (BMD), and microarchitectural features were measured on 29 human cancellous calcaneus samples in vitro. Regression analysis was performed to predict ultrasound parameters from BMD and microarchitectural features. The best univariate predictors of the ultrasound parameters were the indexes of bone quantity: BMD and bone volume fraction (BV/TV). The most predictive univariate models for attenuation, phase velocity, and backscatter coefficient yielded adjusted squared correlation coefficients of 0.69-0.73. Multiple regression models yielded adjusted correlation coefficients of 0.74-0.83. Therefore attenuation, phase velocity, and backscatter are primarily determined by bone quantity, but multiple regression models based on bone quantity plus microarchitectural features achieve slightly better predictive performance than models based on bone quantity alone.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.