ArticleJournal of clinical monitoring and computing2012
Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output.
Article in Journal of clinical monitoring and computing, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02841046 (The Application of Goal-directed Therapy With the Combination of Stroke Volume Variation and Cardiac Index as the Primary Judgment in Non-severe Patients Underwent Gastrointestinal Tumor Surgery), which is not on this map. Cited by 9 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Application of Goal-directed Therapy With the Combination of Stroke Volume Variation and Cardiac Index as the Primary Judgment in Non-severe Patients Underwent Gastrointestinal Tumor Surgery
Who cites it
9 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Agreement of minimally invasive pulse wave analysis with pulmonary artery and transpulmonary thermodilution cardiac output measurements in perioperative and intensive care medicine: a systematic review and meta-analysis.British journal of anaesthesia · 2026Pooled it
- Risk factors for a central-to-peripheral arterial blood pressure gradient in adults: a systematic review.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2025Pooled it
- Risk factors for postoperative myocardial injury-related cardiogenic shock in patients undergoing cardiac surgery.Journal of cardiothoracic surgery · 2023Article
- Accuracy of non-invasive and minimally invasive hemodynamic monitoring: where do we stand?Annals of translational medicine · 2019Review
- Agreement in hemodynamic monitoring during orthotopic liver transplantation: a comparison of FloTrac/Vigileo at two monitoring sites with pulmonary artery catheter thermodilution.Journal of clinical monitoring and computing · 2017Observational
- The value of arterial pressure waveform cardiac output measurements in the radial and femoral artery in major cardiac surgery patients.BMC anesthesiology · 2017Article
- Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre.Journal of clinical monitoring and computing · 2016Observational
- Minimally invasive or noninvasive cardiac output measurement: an update.Journal of anesthesia · 2016Review
- Performance of Third-generation FloTrac/Vigileo system during hyperdynamic therapy for delayed cerebral ischemia after subarachnoid hemorrhage.Surgical neurology international · 2012Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The present study was conducted to study the effect of monitoring site, radial or femoral, for arterial pressure waveform derived cardiac output using FloTrac/Vigileo system with third generation software version 3.02 during cardiac surgery. The cardiac output derived from the two sites was also compared to the pulmonary artery catheter (PAC) derived cardiac output to reevaluate the relation between them using the newer software. The effect of cardiopulmonary bypass (CPB) was also studied by doing the sub analysis before and after bypass. Forty patients undergoing coronary artery bypass surgery with cardiopulmonary bypass were enrolled in the study. Cardiac output derived from radial artery (RADCO), femoral artery (FEMCO) using FloTrac/Vigileo system with third generation software version 3.02 and cardiac output using pulmonary artery catheter (PACCO) at predefined nine time points were recorded. Three hundred and forty two cardiac output data triplets were analysed. The Bland-Altman analysis of RADCO and FEMCO revealed a mean bias of -0.28 with percentage error of 20%. The pre CPB precision of both RADCO and FEMCO was 1.25 times as that of PACCO. The post CPB precision of FEMCO was 1.2 times of PACCO while that of RADCO was 1.7 times of PACCO. The third generation of FloTrac/Vigileo system shows good correlation between the radial and femoral derived cardiac outputs in both pre and post bypass periods. The newer software correlates better to PAC derived cardiac output in the post bypass period for femoral artery than radial artery.
Indexed as
Identifiers
22350311What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.