ArticleWorld journal of gastrointestinal endoscopy2012
Blue mode does not offer any benefit over white light when calculating Lewis score in small-bowel capsule endoscopy.
Article in World journal of gastrointestinal endoscopy, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed.
- Mucosal healing effect of mesalazine granules in naproxen-induced small bowel enteropathy.World journal of gastroenterology · 2013Trial
- Virtual Chromoendoscopy in Capsule Endoscopy: A Narrative Review.Diagnostics (Basel, Switzerland) · 2022Review
- Algorithmic Approach to Inflammatory Disorders of Ileum.Iranian journal of pathology · 2022Review
- Endoscopic capsule robot-based diagnosis, navigation and localization in the gastrointestinal tract.Frontiers in robotics and AI · 2022Review
- Capsule Endoscopy in Inflammatory Bowel Disease: When? To Whom?Diagnostics (Basel, Switzerland) · 2021Review
- Small-Bowel Capsule Endoscopy-Optimizing Capsule Endoscopy in Clinical Practice.Diagnostics (Basel, Switzerland) · 2021Review
- Image-Enhanced Capsule Endoscopy Improves the Identification of Small Intestinal Lesions.Diagnostics (Basel, Switzerland) · 2021Review
- Video capsule endoscopy: pushing the boundaries with software technology.Translational gastroenterology and hepatology · 2021Review
- Performance measures for small-bowel endoscopy: A European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative.United European gastroenterology journal · 2019Review
- Optimising the performance and interpretation of small bowel capsule endoscopy.Frontline gastroenterology · 2018Review
- Capsule endoscopy of the small bowel.Annals of translational medicine · 2016Review
- Association Between Fecal Calprotectin Levels and Small-bowel Inflammation Score in Capsule Endoscopy: A Multicenter Retrospective Study.Digestive diseases and sciences · 2016Article
- Usefulness of virtual chromoendoscopy in the evaluation of subtle small bowel ulcerative lesions by endoscopists with no experience in videocapsule.Endoscopy international open · 2016Article
- Is virtual chromoendoscopy useful in the evaluation of subtle ulcerative small-bowel lesions detected by video capsule endoscopy?Endoscopy international open · 2015Article
- Use of enhancement algorithm to suppress reflections in 3-D reconstructed capsule endoscopy images.World journal of gastrointestinal endoscopy · 2013Article
- Novel imaging enhancements in capsule endoscopy.Gastroenterology research and practice · 2013Article
- Artificial intelligence for the detection of polyps or cancer with colon capsule endoscopy.Therapeutic advances in gastrointestinal endoscopyReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimTo check the usefulness of blue mode (BM) review in lewis score (LS) calculation, by comparing it with respective LS results obtained by white light (WL) small-bowel capsule endoscopy (SBCE) review and mucosal inflammation as reflected by faecal calprotectin (FC) levels, considered as 'gold standard' for this study.
methodsComputational analysis of our SBCE database to identify patients who underwent SBCE with PillCam(®) and had FC measured within a 30-day period from their test. Only patients with prior colonoscopy were included, to exclude any colon pathology-associated FC rise. Each small bowel tertile was reviewed (viewing speed 8 fps) with WL and BM, in a back-to-back mode, by a single experienced reviewer. LS were calculated after each WL and BM reviews. Pearson rank correlation (rho, r) statistic was applied.
resultsTwenty-seven (n = 27, 20F/7M) patients were included. Thirteen (n = 13) had SBCE with PillCam(®)SB1, and the remainder (n = 14) with PillCam(®)SB2. The median level of FC in this cohort was 125 μg/g. LS (calculated in WL SBCE review) correlation with FC levels was r = 0.490 (P = 0.01), while for BM review and LS correlation with FC was r = 0.472 (P = 0.013).
conclusionAlthough BM is believed to enhance mucosal details i.e., small mucosal breaks, it did not perform better than WL in the calculation of LS in our cohort.