Evidence map›Paper›PMID 22344487›Full record

ArticleLab on a chip2012

Spinning magnetic trap for automated microfluidic assay systems.

Jasenka Verbarg, Kian Kamgar-Parsi, Adam R Shields, Peter B Howell, Frances S Ligler

Open access · greenAbstract read
In one paragraph

Article in Lab on a chip, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
3.1field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 39 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Jasenka VerbargNaval Research Laboratory, 4555 Overlook Avenue, SW, Washington, DC 20375, USA.
Kian Kamgar-Parsi
Adam R Shields
Peter B Howell
Frances S Ligler
United States Naval Research Laboratory · US

Funding

Partnership for Detection of Infection by Category B PathogensU01AI075489 · NIAID · U.S. NAVAL RESEARCH LABORATORY · PI LIGLER, FRANCES S. · 2007 to 2011
$4.0M
NIAID NIH HHS U01 AI075489PHS HHS U01 A1075489
6 · The paper itself

Abstract

While sophisticated analyses have been performed using lab-on-chip devices, in most cases the sample preparation is still performed off chip. The global need for easy-to-use, disposable testing devices necessitates that sample processing is automated and that transport complexity between the processing and analytical components is minimal. We describe a complete sample manipulation unit for performing automated target capture, efficient mixing with reagents, and controlled target release in a microfluidic channel, using an array of spinning magnets. The "MagTrap" device consists of 6 pairs of magnets in a rotating wheel, situated immediately beneath the microchannel. Rotation of the wheel in the direction opposite to the continuous flow entraps and concentrates the bead-target complexes and separates them from the original sample matrix. As the wheel rotates and the active pair of magnets moves away from the microchannel, the beads are released and briefly flow downstream before being trapped and pulled upstream by the next pair of magnets. This dynamic and continuous movement of the beads ensures that the full surface area of each bead is exposed to reagents and prevents aggregation. The release of the target-bead complexes for further analysis is facilitated by reversing the rotational direction of the wheel to sweep the beads downstream. Sample processing with the MagTrap was demonstrated for the detection of E. coli in a range of concentrations (1 × 10(3), 1 × 10(4) and 1 × 10(6) cells ml(-1)). Results show that sample processing with the MagTrap outperformed the standard manual protocols, improving the detection capability while simultaneously reducing the processing time.

Indexed as

MagnetsEquipment DesignEscherichia coliFluorescent DyesImmunoassayImmunoglobulin GImmunomagnetic SeparationMicrofluidic Analytical TechniquesMicrospheresModels, TheoreticalFluorescent DyesImmunoglobulin G

Identifiers

PMID22344487
PMCPMC3641145
OpenAlexW2066940483

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.