Evidence map›Paper›PMID 22336786›Full record

SynthesisThe Cochrane database of systematic reviews2012

Stapled versus handsewn methods for colorectal anastomosis surgery.

Cristiane B Neutzling, Suzana A S Lustosa, Igor M Proenca, Edina M K da Silva, Delcio Matos

Registry-linked trialOpen access · greenAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04578392 (MeSenteric SpAring Versus High Ligation Ileocolic Resection for the Prevention of REcurrent Crohn's DiseaSe), which is not on this map. Cited by 111 papers, 7 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
111citing papers in PubMed, 7 pooled it
15.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04578392 naterminatednot on this mapstarted 2020, after this paper: background citation

MeSenteric SpAring Versus High Ligation Ileocolic Resection for the Prevention of REcurrent Crohn's DiseaSe (SPARES)

TypeinterventionalSponsorThe Cleveland ClinicRan2020 to 2023Enrolled13ConditionsCrohn DiseaseArmshigh ligation of ileocolic artery, mesenteric sparing
3 · Its place in the literature

Who cites it

111 citing papers in PubMed, 7 syntheses or guidelines pooled it, 439 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Pooled it
  7. Pooled it
  8. Trial
  9. Trial
  10. Single-Layer Continuous Versus Double-Layer Continuous Suture in Colonic Anastomoses-a Randomized Multicentre Trial (ANATECH Trial).Journal of gastrointestinal surgery : official journal of the Society for Surgery of the Alimentary Tract · 2016
    Trial
  11. Review
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article

51 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Cristiane B NeutzlingInterdisciplinary Surgical Science Program,UNIFESP-Escola Paulista deMedicina, São Paulo, Brazil.
Suzana A S Lustosa
Igor M Proenca
Edina M K da Silva
Delcio Matos
Universidade Federal de São Paulo · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPrevious systematic reviews comparing stapled and handsewn colorectal anastomosis that are available in the medical literature have not shown either technique to be superior. An update of this systematic review was performed to find out if there are any data that properly answer this question.

objectivesTo compare the safety and effectiveness of stapled and handsewn colorectal anastomosis surgery. The following primary hypothesis was tested: the stapled technique is more effective because it decreases the level of complications. SEARCH

methodsA computerized search was performed in the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE according to the strategies of the Colorectal Cancer Group of The Cochrane Collaboration. There were no limits upon language, date or other criteria. A revised search strategy was performed for this updated version of the review May 2011. SELECTION CRITERIA: All randomised controlled trials (RCTs) in which stapled and handsewn colorectal anastomosis techniques were compared. Participants were adult patients undergoing elective colorectal anastomosis surgery. The interventions were endoluminal circular stapler and handsewn colorectal anastomosis surgery. Outcomes considered were a) mortality; b) overall anastomotic dehiscence; c) clinical anastomotic dehiscence; d) radiological anastomotic dehiscence; e) stricture; f) anastomotic haemorrhage; g) reoperation; h) wound infection; i) anastomosis duration; and j) hospital stay. DATA COLLECTION AND ANALYSIS: Data were independently analysed by the two review authors (CBN, SASL) and cross-checked. The methodological quality of each trial was assessed by the same two authors. After searching the literature for this update, no study was added to those in the previous version of this review. Details of randomizations (generation and concealment), blinding, whether an intention-to-treat analysis was done or not, and the number of patients lost to follow-up were recorded. The analysis of the risk of bias was updated according to the software Review Manager 5.1. The results of each RCT were summarized on an intention-to-treat basis in 2 x 2 tables for each outcome. External validity was defined by the characteristics of the participants, interventions and the outcomes. The RCTs were stratified according to the level of colorectal anastomosis. The risk difference (RD) method (random-effects model) and number needed to treat (NNT) for dichotomous outcome measures and weighted mean differences (WMD) for continuous outcomes measures, with the corresponding 95% confidence intervals (CI), were presented in this review. Statistical heterogeneity was evaluated using a funnel plot and the Chi(2) test. MAIN

resultsOf the 1233 patients enrolled in nine identified trials, 622 were treated with staples and 611 with manual suture. The following main results were obtained. a) Mortality, result based on 901 patients: RD -0.6%, 95% CI -2.8% to +1.6%. b) Overall dehiscence, result based on 1233 patients: RD 0.2%, 95% CI -5.0% to +5.3%. c) Clinical anastomotic dehiscence, result based on 1233 patients: RD -1.4%, 95% CI -5.2 to +2.3%. d) Radiological anastomotic dehiscence, result based on 825 patients: RD 1.2%, 95% CI -4.8% to +7.3%. e) Stricture, result based on 1042 patients: RD 4.6%, 95% CI 1.2% to 8.1%; NNT 17, 95% CI 12 to 31. f) Anastomotic haemorrhage, result based on 662 patients: RD 2.7%, 95% CI -0.1% to +5.5%. g) Reoperation, result based on 544 patients: RD 3.9%, 95% CI 0.3% to 7.4%. h) Wound infection, result based on 567 patients: RD 1.0%, 95% CI -2.2% to +4.3%. i) Anastomosis duration, result based on one study (159 patients): WMD -7.6 minutes, 95% CI -12.9 to -2.2 minutes. j) Hospital stay, result based on one study (159 patients): WMD 2.0 days, 95% CI -3.27 to +7.2 days. AUTHORS'

conclusionsThe evidence found was insufficient to demonstrate any superiority of stapled over handsewn techniques in colorectal anastomosis surgery, regardless of the level of anastomosis. There were no randomised clinical trials comparing these two types of anastomosis in elective conditions in the last decade. The relevance of this research question has possibly lost its strength where elective surgery is concerned. However, in risk situations, such as emergency surgery, trauma and inflammatory bowel disease, new clinical trials are needed.

Indexed as

Suture TechniquesAdultAnastomosis, SurgicalColonHumansRandomized Controlled Trials as TopicRectumSurgical Stapling

Identifiers

PMID22336786
PMCPMC12009662
OpenAlexW1556632790

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.