Evidence map›Paper›PMID 22315552›Full record

ArticleSensors (Basel, Switzerland)2010

Optimal clinical time for reliable measurement of transcutaneous CO2 with ear probes: counterbalancing overshoot and the vasodilatation effect.

Christian Domingo, Elisa Canturri, Amalia Moreno, Humildad Espuelas, Laura Vigil, Manel Luján

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Observational
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Christian DomingoPneumology Service, Hospital de Sabadell, Corporació Parc Taulí, Sabadell 08208, Spain. cdomingo@tauli.cat
Elisa Canturri
Amalia Moreno
Humildad Espuelas
Laura Vigil
Manel Luján
Universitat Autònoma de Barcelona · ESDeleted Institution

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo determine the optimal clinical reading time for the transcutaneous measurement of oxygen saturation (SpO(2)) and transcutaneous CO(2) (TcPCO(2)) in awake spontaneously breathing individuals, considering the overshoot phenomenon (transient overestimation of arterial PaCO(2)). EXPERIMENTAL SECTION: Observational study of 91 (75 men) individuals undergoing forced spirometry, measurement of SpO(2) and TcPCO(2) with the SenTec monitor every two minutes until minute 20 and arterial blood gas (ABG) analysis. Overshoot severity: (a) mild (0.1-1.9 mm Hg); (b) moderate (2-4.9 mm Hg); (c) severe: (>5 mm Hg). The mean difference was calculated for SpO(2) and TcPCO(2) and arterial values of PaCO(2) and SpO(2). The intraclass correlation coefficient (ICC) between monitor readings and blood values was calculated as a measure of agreement.

resultsThe mean age was 63.1 ± 11.8 years. Spirometric values: FVC: 75.4 ± 6.2%; FEV(1): 72.9 ± 23.9%; FEV(1)/FVC: 70 ± 15.5%. ABG: PaO(2): 82.6 ± 13.2; PaCO(2): 39.9.1 ± 4.8 mmHg; SaO(2): 95.3 ± 4.4%. Overshoot analysis: overshoot was mild in 33 (36.3%) patients, moderate in 20 (22%) and severe in nine (10%); no overshoot was observed in 29 (31%) patients. The lowest mean differences between arterial blood gas and TcPCO(2) was -0.57 mmHg at minute 10, although the highest ICC was obtained at minutes 12 and 14 (>0.8). The overshoot lost its influence after minute 12. For SpO(2), measurements were reliable at minute 2.

conclusionsThe optimal clinical reading measurement recommended for the ear lobe TcPCO(2) measurement ranges between minute 12 and 14. The SpO(2) measurement can be performed at minute 2.

Indexed as

EarTransducersAdultBlood Gas AnalysisEquipment DesignEquipment Failure AnalysisHumansMaleMiddle AgedReproducibility of ResultsSensitivity and SpecificitySkinVasodilationoptimal reading timeovershoot phenomenontranscutaneous CO2

Identifiers

PMID22315552
PMCPMC3270853
OpenAlexW1980365321

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.