Evidence map›Paper›PMID 22300938›Full record

ArticleAJNR. American journal of neuroradiology2012

A comparison of 2 stroke devices: the new Aperio clot-removal device and the solitaire AB/FR.

C Roth, D Junk, P Papanagiotou, A Keuler, H Körner, M Schumacher, W Reith

Open access · bronzeAbstract readComparative Study
In one paragraph

Article in AJNR. American journal of neuroradiology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it, 31 citations in OpenAlex.

  1. Large animals in neurointerventional research: A systematic review on models, techniques and their application in endovascular procedures for stroke, aneurysms and vascular malformations.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2019
    Pooled it
  2. A novel method for preparing clot analogs under dynamic vortical flow for testing mechanical thrombectomy devices.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  3. Review
  4. Comparison of the Aperio HybridInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
  10. Review
  11. Efficacy of Solitaire Stent Arterial Embolectomy in Treating Acute Cardiogenic Cerebral Embolism in 17 Patients.Medical science monitor : international medical journal of experimental and clinical research · 2016
    Article
  12. Article
  13. What is meant by "TICI"?AJNR. American journal of neuroradiology · 2013
    Review
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

C RothClinic for Diagnostic and Interventional Neuroradiology, Saarland University Hospital, Homburg/Saar, Germany. Christian.roth@uks.eu
D Junk
P Papanagiotou
A Keuler
H Körner
M Schumacher
W Reith
Saarland University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeSeveral studies have shown promising results for the use of self-expandable intracranial stents for the treatment of acute ischemic stroke. This new technique combines immediate flow restoration after stent deployment with high recanalization rates. In the present study, the safety and efficacy of the new Aperio clot-removal device was tested in comparison with the Solitaire AB device. MATERIALS AND

methodsThe experiments were performed in swine with a weight of 35-50 kg following established models. The experimental thrombi were prepared by using a new flow model (Thrombus Loop) to produce radiopaque thrombi. Thrombi were cut into lengths of 10 mm and injected into the target vessel. The occlusion was verified by DSA and rated with the help of the TICI score. A microcatheter was placed distal to the thrombus. The devices were placed with the proximal third within the thrombus and were retrieved under continuous aspiration in their released state into the guiding sheath. We performed 23 procedures with the Aperio device and 18 procedures with the Solitaire AB and FR devices. Control angiograms were obtained 3 and 5 minutes after device deployment to evaluate the flow restoration. The number of attempts to reach a TICI 2/3 score was recorded as well as the time to recanalization and the device-related complications. Vasospasm, vascular perforation, intramural arterial dissection, or embolization of a previously uninvolved territory was defined as a device-related complication.

resultsDefined radiopaque thrombi from whole blood could reliably be created by using the Thrombus Loop. Both devices demonstrated a high recanalization rate of 100% (TICI 3) in the target vessel with no device-related complications. No significant differences were found between the 2 devices.

conclusionsIn this small study, we could show that radiopaque thrombi of whole blood with a defined diameter could be reliably created by using the Thrombus Loop. The new "stent-retriever" (Aperio System) seems to be a very efficient and safe addition to the existing repertoire of clot-removal devices.

Indexed as

AnimalsBrain IschemiaEquipment DesignEquipment Failure AnalysisMechanical ThrombolysisRadiographyStrokeSwineTreatment Outcome

Identifiers

PMID22300938
PMCPMC7965504
OpenAlexW2050653164

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.