Evidence map›Paper›PMID 22294293›Full record

ArticleEuropean journal of applied physiology2012

Validity and reliability of the Horiba C-122 compact sodium analyzer in sweat samples of athletes.

Eric D B Goulet, Tommy Dion, Étienne Myette-Côté

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in European journal of applied physiology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.2field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 15 citations in OpenAlex.

  1. Trial
  2. Article
  3. Physiological mechanisms determining eccrine sweat composition.European journal of applied physiology · 2020
    Review
  4. Review
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Eric D B GouletResearch Centre On Aging, University of Sherbrooke, 1036 Belvédère Sud, Sherbrooke, QC, J1H 4C4, Canada. eric.goulet@usherbrooke.ca
Tommy Dion
Étienne Myette-Côté
Université de Sherbrooke · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate sodium replacement during prolonged exercise is possible when sweat rate and sweat sodium content are directly measured. Few athletes have access to sweat sodium content measurement, as the equipment needed to perform such analyzes is costly, laboratory-based or requires technical skills. Using 70 sweat samples collected in 24 athletes from 3 anatomical sites, this study determined the reliability [single-trial and inter-day (7 samples over 3 days)] and validity (instrument error) of a pocket-sized, easy-to-use and low cost sodium analyzer (Horiba C-122, Kyoto, Japan) against reference values of an ion chromatograph, the 883 Basic IC plus (Metrohm AG, Herisau, Switzerland). The Horiba C-122 showed high single-trial reliability with an intraclass correlation coefficient (ICC) of 0.997, a typical error of measurement (EM) of 1.77 mmol/L and a coefficient of variation (CV) of 3.73%. As expected, the reliability of the 883 Basic IC plus was superior to that of the Horiba C-122 (ICC: 0.999; typical EM: 0.70 mmol/L; CV: 1.52%). The Horiba’s C-122 inter-day reliability was high (ICC: 1.00; typical EM: 0.35 mmol/L). An ICC of 0.975 indicates there was a strong relationship between results provided by both analyzers. Compared with reference values, the Horiba C-122 demonstrated a mean bias of 1.71 mmol/L, a pure EM of 7.52 mmol/L and 68% limits of agreement ranging from -5.81 to 9.23 mmol/L. We propose that the Horiba C-122 is sufficiently reliable to be used under field conditions where some degree of imprecision is acceptable, but not for research purposes where high accuracy is required.

Indexed as

AthletesExerciseFemaleHumansMaleSodiumSweatSweatingSodium

Identifiers

PMID22294293
OpenAlexW2092614260

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.