SynthesisThe Cochrane database of systematic reviews2012
Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin.
Synthesis in The Cochrane database of systematic reviews, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 131 papers, 11 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
131 citing papers in PubMed, 11 syntheses or guidelines pooled it, 361 citations in OpenAlex.
- 2023 Clinical Practice Guidelines for Diabetes Management in Korea: Full Version Recommendation of the Korean Diabetes Association.Diabetes & metabolism journal · 2024Guideline
- The impact of structured self-monitoring of blood glucose on clinical, behavioral, and psychosocial outcomes among adults with non-insulin-treated type 2 diabetes: a systematic review and meta-analysis.Frontiers in clinical diabetes and healthcare · 2023Pooled it
- American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2022Guideline
- Techniques of monitoring blood glucose during pregnancy for women with pre-existing diabetes.The Cochrane database of systematic reviews · 2019Pooled it
- Helping patients help themselves: A systematic review of self-management support strategies in primary health care practice.PloS one · 2019Pooled it
- Effects of Structured Versus Unstructured Self-Monitoring of Blood Glucose on Glucose Control in Patients With Non-insulin-treated Type 2 Diabetes: A Meta-Analysis of Randomized Controlled Trials.Journal of diabetes science and technology · 2018Pooled it
- Tailored Communication Within Mobile Apps for Diabetes Self-Management: A Systematic Review.Journal of medical Internet research · 2017Pooled it
- Techniques of monitoring blood glucose during pregnancy for women with pre-existing diabetes.The Cochrane database of systematic reviews · 2017Pooled it
- Pooled it
- Characterizing patient-oriented tools that could be packaged with guidelines to promote self-management and guideline adoption: a meta-review.Implementation science : IS · 2016Pooled it
- A Systematic Review Exploring the Social Cognitive Theory of Self-Regulation as a Framework for Chronic Health Condition Interventions.PloS one · 2015Pooled it
- Village doctor-led integrated care for older adults with diabetes in rural China: a cluster-randomized pilot trial.BMC geriatrics · 2026Trial
- Effectiveness of a Social Networking Site Based Automatic Mobile Message Providing System on Glycemic Control in Patients with Type 2 Diabetes Mellitus.Endocrinology and metabolism (Seoul, Korea) · 2024Trial
- Electronic blood glucose monitoring impacts on provider and patient behavior.Journal of the American Medical Informatics Association : JAMIA · 2022Trial
- Users' acceptability of a mobile application for persons with type 2 diabetes: a qualitative study.BMC health services research · 2019Trial
- Self-Monitoring of Blood Glucose in Youth-Onset Type 2 Diabetes: Results From the TODAY Study.Diabetes care · 2019 · on this mapTrial
- Effect of structured self-monitoring of blood glucose, with and without additional TeleCare support, on overall glycaemic control in non-insulin treated Type 2 diabetes: the SMBG Study, a 12-month randomized controlled trial.Diabetic medicine : a journal of the British Diabetic Association · 2019Trial
- Valuing injection frequency and other attributes of type 2 diabetes treatments in Australia: a discrete choice experiment.BMC health services research · 2018Trial
- Effectiveness of a Self-monitoring Device for Urinary Sodium-to-Potassium Ratio on Dietary Improvement in Free-Living Adults: a Randomized Controlled Trial.Journal of epidemiology · 2018Trial
- Glucose Self-monitoring in Non-Insulin-Treated Patients With Type 2 Diabetes in Primary Care Settings: A Randomized Trial.JAMA internal medicine · 2017Trial
71 more citing papers are in PubMed but not listed here.
Corrections and comments
- Update of
Authors and funding
6 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSelf-monitoring of blood glucose (SMBG) has been found to be effective for patients with type 1 diabetes and for patients with type 2 diabetes using insulin. There is much debate on the effectiveness of SMBG as a tool in the self-management for patients with type 2 diabetes who are not using insulin.
objectivesTo assess the effects of SMBG in patients with type 2 diabetes mellitus who are not using insulin. SEARCH
methodsMultiple electronic bibliographic and ongoing trial databases were searched supplemented with handsearches of references of retrieved articles (date of last search: 07 July 2011). SELECTION CRITERIA: Randomised controlled trials investigating the effects of SMBG compared with usual care, self-monitoring of urine glucose (SMUG) or both in patients with type 2 diabetes who where not using insulin. Studies that used glycosylated haemoglobin A(1c) (HbA(1c)) as primary outcome were eligible for inclusion. DATA COLLECTION AND ANALYSIS: Two authors independently extracted data from included studies and evaluated the studies' risk of bias. Data from the studies were compared to decide whether they were sufficiently homogeneous to pool in a meta-analysis. Primary outcomes were HbA(1c), health-related quality of life, well-being and patient satisfaction. Secondary outcomes were fasting plasma glucose level, hypoglycaemic episodes, morbidity, adverse effects and costs. MAIN
resultsTwelve randomised controlled trials were included and evaluated outcomes in 3259 randomised patients. Intervention duration ranged from 6 months (26 weeks) to 12 months (52 weeks). Nine trials compared SMBG with usual care without monitoring, one study compared SMBG with SMUG, one study was a three-armed trial comparing SMBG and SMUG with usual care and one study was a three-armed trial comparing less intensive SMBG and more intensive SMBG with a control group. Seven out of 11 studies had a low risk of bias for most indicators. Meta-analysis of studies including patients with a diabetes duration of one year or more showed a statistically significant SMBG induced decrease in HbA(1c) at up to six months follow-up (-0.3; 95% confidence interval (CI) -0.4 to -0.1; 2324 participants, nine trials), yet an overall statistically non-significant SMBG induced decrease was seen at 12 month follow-up (-0.1; 95% CI -0.3 to 0.04; 493 participants, two trials). Qualitative analysis of the effect of SMBG on well-being and quality of life showed no effect on patient satisfaction, general well-being or general health-related quality of life. Two trials reported costs of self-monitoring: One trial compared the costs of self-monitoring of blood glucose with self-monitoring of urine glucose based on nine measurements per week and with the prices in US dollars for self-monitoring in 1990. Authors concluded that total costs in the first year of self-monitoring of blood glucose, with the purchase of a reflectance meter were 12 times more expensive than self-monitoring of urine glucose ($481 or 361 EURO [11/2011 conversion] versus $40 or 30 EURO [11/2011 conversion]). Another trial reported a full economical evaluation of the costs and effects of self-monitoring. At the end of the trial, costs for the intervention were £89 (104 EURO [11/2011 conversion]) for standardized usual care (control group), £181 (212 EURO [11/2011 conversion]) for the less intensive self-monitoring group and £173 (203 EURO [11/2011 conversion]) for the more intensive self-monitoring group. Higher losses to follow-up in the more intensive self-monitoring group were responsible for the difference in costs, compared to the less intensive self-monitoring group.There were few data on the effects on other outcomes and these effects were not statistically significant. None of the studies reported data on morbidity. AUTHORS'
conclusionsFrom this review, we conclude that when diabetes duration is over one year, the overall effect of self-monitoring of blood glucose on glycaemic control in patients with type 2 diabetes who are not using insulin is small up to six months after initiation and subsides after 12 months. Furthermore, based on a best-evidence synthesis, there is no evidence that SMBG affects patient satisfaction, general well-being or general health-related quality of life. More research is needed to explore the psychological impact of SMBG and its impact on diabetes specific quality of life and well-being, as well as the impact of SMBG on hypoglycaemia and diabetic complications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.