ReviewKorean journal of radiology
CT radiation dose optimization and estimation: an update for radiologists.
Review in Korean journal of radiology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 107 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
107 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Artificial intelligence in personalized computed tomography dose optimization: a systematic review of techniques and clinical outcomes.Frontiers in medicine · 2026Pooled it
- CT venography for deep vein thrombosis using a low tube voltage (100 kVp) setting could increase venous enhancement and reduce the amount of administered iodine.Korean journal of radiologyTrial
- Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial for Comparison with Conventional CT Urography.Korean journal of radiologyTrial
- Coronary artery imaging in Kawasaki disease: recent updates in imaging techniques and clinical indications.The international journal of cardiovascular imaging · 2026Review
- Institutional CT dose reduction: A retrospective evaluation of dose indices from 2015-2024.Journal of applied clinical medical physics · 2026Article
- Establishing institutional adult computed tomography diagnostic reference levels at a public tertiary hospital in Singapore.Singapore medical journal · 2026Article
- Developing Congenital Cardiac CT Services in Low-Resource Settings: A Quality Improvement Approach.Pediatric cardiology · 2026Article
- Contemporary strategies for dose optimization in pediatric congenital heart disease CT: size-specific acquisition and detector-level advances.Radiological physics and technology · 2026Review
- Impact of calcium suppression imaging on hand and wrist fracture detection in spectral CT: a comparison with X-ray and CT.Skeletal radiology · 2026Article
- Multi-modal low-dose medical imaging through instruction-guided unified AI.Frontiers in medicine · 2026Article
- [Computed tomography of the chest in children : Indications, technical optimization, and future perspectives].Radiologie (Heidelberg, Germany) · 2025Review
- Establishment of the first National diagnostic reference levels by clinical indication for adult head computed tomography in morocco: A baseline study.Emergency radiology · 2025Article
- Computed tomography for major aortopulmonary collateral arteries: a roadmap to unifocalized pulmonary arterial flow.Pediatric radiology · 2025Review
- Establishing Diagnostic Reference Levels for Paediatric CT Imaging: A Multi-Centre Study.Healthcare (Basel, Switzerland) · 2025Article
- Achieving low radiation dose and contrast agents dose in coronary CT angiography at 60-kVp ultra-low tube voltage.BMC medical imaging · 2025Article
- Visualization of X-ray fields, overlaps, and over-beaming on surface of the head in spiral computed tomography using computer-aided design-based X-ray beam modeling.Radiological physics and technology · 2025Article
- Development of Acceptable Quality Dose (AQD) and image quality-related diagnostic reference levels for common computed tomography investigations in a tertiary care public sector hospital of Khyber Pakhtunkhwa, Pakistan.Japanese journal of radiology · 2024Article
- Comparison of doses received from non-contrast enhanced brain CT examinations between two CT scanners.Heliyon · 2024Article
- Optimization of Fast Non-Local Means Noise Reduction Algorithm Parameter in Computed Tomographic Phantom Images Using 3D Printing Technology.Diagnostics (Basel, Switzerland) · 2024Article
- An Analysis of Computed Tomography Diagnostic Reference Levels in India Compared to Other Countries.Diagnostics (Basel, Switzerland) · 2024Review
47 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In keeping with the increasing utilization of CT examinations, the greater concern about radiation hazards from examinations has been addressed. In this regard, CT radiation dose optimization has been given a great deal of attention by radiologists, referring physicians, technologists, and physicists. Dose-saving strategies are continuously evolving in terms of imaging techniques as well as dose management. Consequently, regular updates of this issue are necessary especially for radiologists who play a pivotal role in this activity. This review article will provide an update on how we can optimize CT dose in order to maximize the benefit-to-risk ratio of this clinically useful diagnostic imaging method.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials