Evidence map›Paper›PMID 22242099›Full record

ArticleGMS Krankenhaushygiene interdisziplinar2011

Incidence and clinical implication of nosocomial infections associated with implantable biomaterials - catheters, ventilator-associated pneumonia, urinary tract infections.

Josef Peter Guggenbichler, Ojan Assadian, Michael Boeswald, Axel Kramer

Open access · greenAbstract read
In one paragraph

Article in GMS Krankenhaushygiene interdisziplinar, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 61 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
61citing papers in PubMed, 1 pooled it
5.8field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

61 citing papers in PubMed, 1 synthesis or guideline pooled it, 148 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Effects of sterilization treatments on bulk and surface properties of nanocomposite biomaterials.Journal of biomedical materials research. Part B, Applied biomaterials · 2013
    Trial
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Review
  13. Review
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. ClinicalMicroorganisms · 2022
    Review

1 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Josef Peter GuggenbichlerUniv. Erlangen, Department of Pediatrics and Ped. Infectious Diseases, Erlangen, Germany.
Ojan Assadian
Michael Boeswald
Axel Kramer
Friedrich-Alexander-Universität Erlangen-Nürnberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Health care associated infections, the fourth leading cause of disease in industrialised countries, are a major health issue. One part of this condition is based on the increasing insertion and implantation of prosthetic medical devices, since presence of a foreign body significantly reduces the number of bacteria required to produce infection. The most significant hospital-acquired infections, based on frequency and potential severity, are those related to procedures e.g. surgical site infections and medical devices, including urinary tract infection in catheterized patients, pneumonia in patients intubated on a ventilator and bacteraemia related to intravascular catheter use. At least half of all cases of nosocomial infections are associated with medical devices.Modern medical and surgical practices have increasingly utilized implantable medical devices of various kinds. Such devices may be utilized only short-time or intermittently, for months, years or permanently. They improve the therapeutic outcome, save human lives and greatly enhance the quality of life of these patients. However, plastic devices are easily colonized with bacteria and fungi, able to be colonized by microorganisms at a rate of 0.5 cm per hour. A thick biofilm is formed within 24 hours on the entire surface of these plastic devices once inoculated even with a small initial number of bacteria.The aim of the present work is to review the current literature on causes, frequency and preventive measures against infections associated with intravascular devices, catheter-related urinary tract infection, ventilator-associated infection, and infections of other implantable medical devices. Raising awareness for infection associated with implanted medical devices, teaching and training skills of staff, and establishment of surveillance systems monitoring device-related infection seem to be the principal strategies used to achieve reduction and prevention of such infections. The intelligent use of suitable antiseptics in combination with medical devices may further support reduction and prevention of such infections. In addition to reducing the adverse clinical outcomes related with these infections, such reduction may substantially decrease the economic burden caused by device-related infection for health care systems.

Indexed as

catheter related blood stream infectionshospital-acquired infectionsmedical device associated infectionspace maker infectionspreventionprosthetic joint infectionssurveillanceurinary tract infectionsvascular graft infectionsventilator-associated pneumonia

Identifiers

PMID22242099
PMCPMC3252661
OpenAlexW169847975

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.