Evidence map›Paper›PMID 22225232›Full record

ArticleThe Review of scientific instruments2011

A gain and bandwidth enhanced transimpedance preamplifier for Fourier-transform ion cyclotron resonance mass spectrometry.

Tzu-Yung Lin, Roger J Green, Peter B O'Connor

Abstract read
In one paragraph

Article in The Review of scientific instruments, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Tzu-Yung LinSchool of Engineering, University of Warwick, Coventry, United Kingdom.
Roger J Green
Peter B O'Connor

Funding

XI INTERNATIONAL SYMPOSIUM ON AMYLOIDOSISP41RR010888 · NCRR · BOSTON UNIVERSITY MEDICAL CAMPUS · PI ZAIA, JOSEPH · 1996 to 2011
$18.6M
Defining the IsoAspartomeR01GM078293 · NIGMS · BOSTON UNIVERSITY MEDICAL CAMPUS · PI LIN, CHENG · 2007 to 2011
$1.5M
NCRR NIH HHS P41 RR010888NCRR NIH HHS P41 RR10888NIGMS NIH HHS R01 GM078293NIGMS NIH HHS R01GM078293
6 · The paper itself

Abstract

The nature of the ion signal from a 12-T Fourier-transform ion cyclotron resonance mass spectrometer and the electronic noise were studied to further understand the electronic detection limit. At minimal cost, a new transimpedance preamplifier was designed, computer simulated, built, and tested. The preamplifier design pushes the electronic signal-to-noise performance at room temperature to the limit, because of its enhanced tolerance of the capacitance of the detection device, lower intrinsic noise, and larger flat mid-band gain (input current noise spectral density of around 1 pA/√Hz when the transimpedance is about 85 dBΩ). The designed preamplifier has a bandwidth of ~3 kHz to 10 MHz, which corresponds to the mass-to-charge ratio, m/z, of approximately 18 to 61 k at 12 T. The transimpedance and the bandwidth can be easily adjusted by changing the value of passive components. The feedback limitation of the circuit is discussed. With the maximum possible transimpedance of 5.3 MΩ when using an 0402 surface mount resistor, the preamplifier was estimated to be able to detect ~110 charges in a single scan.

Indexed as

CyclotronsFourier AnalysisComputer SimulationElectric ImpedanceEquipment DesignMass Spectrometry

Identifiers

PMID22225232
PMCPMC3253747

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.