ArticleMagnetic resonance in medicine2012

SWIFT-CEST: a new MRI method to overcome T₂ shortening caused by PARACEST contrast agents.

Todd C Soesbe, Osamu Togao, Masaya Takahashi, A Dean Sherry

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Phenols as Diamagnetic TChemistry (Weinheim an der Bergstrasse, Germany) · 2018
    Article
  3. Article
  4. Article
  5. Detection of in vivo enzyme activity with CatalyCEST MRI.Magnetic resonance in medicine · 2014
    Article
  6. Review
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Todd C SoesbeAdvanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, United States of America.
Osamu Togao
Masaya Takahashi
A Dean Sherry

Funding

YTTRIUM HYPERPOLARIZATIONP41RR002584 · NCRR · UT SOUTHWESTERN MEDICAL CENTER · PI MASON, RALPH P. · 1985 to 2011
$14.3M
PARACEST Agents: Optimization for Human MR ImagingR01EB004582 · NIBIB · UT SOUTHWESTERN MEDICAL CENTER · PI LENKINSKI, ROBERT E · 2006 to 2014
$7.5M
PARACEST AGENTS FOR MOLECULAR IMAGING OF CANCER BY MRIR01CA115531 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI SHERRY, DEAN · 2005 to 2021
$4.2M
UT Southwestern Small Animal Imaging ResourceU24CA126608 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI MASON, RALPH P., SHERRY, DEAN · 2007 to 2011
$2.3M
NCI NIH HHS CA-115531NCI NIH HHS R01 CA115531NCI NIH HHS U24 CA126608NCRR NIH HHS P41 RR002584NCRR NIH HHS RR-02584NIBIB NIH HHS EB-004582NIBIB NIH HHS R01 EB004582
6 · The paper itself

Abstract

The exchange of water molecules between the inner sphere of a paramagnetic chemical exchange saturation transfer (PARACEST) contrast agent and bulk water can shorten the bulk water T(2) through the T(2) -exchange (T(2ex) ) mechanism. The line-broadening T(2ex) effect is proportional to the agent concentration, the chemical shift of the exchanging water molecule, and is highly dependent on the water molecule exchange rate. A significant T(2ex) contribution to the bulk water linewidth can make the regions of agent uptake appear dark when imaging with conventional sequences like gradient-echo and fast spin-echo. The minimum echo times for these sequences (1-10 ms) are not fast enough to capture signal from the regions of shortened T(2) . This makes "Off" (saturation at -Δω) minus "On" (saturation at +Δω) imaging of PARACEST agents difficult, because the regions of uptake are dark in both images. It is shown here that the loss of bulk water signal due to T(2ex) can be reclaimed using the ultrashort echo times (<10 μs) achieved with the sweep imaging with Fourier transform pulse sequence. Modification of the sweep imaging with Fourier transform sequence for PARACEST imaging is first discussed, followed by parameter optimization using in vitro experiments. In vivo PARACEST studies comparing fast spin-echo to sweep imaging with Fourier transform were performed using EuDOTA-(gly) 4- uptake in healthy mouse kidneys. The results show that the negative contrast caused by T(2ex) can be overcome using the ultrashort echo time achieved with sweep imaging with Fourier transform, thereby enabling fast and sensitive in vivo PARACEST imaging.

Indexed as

AlgorithmsArtifactsCoordination ComplexesAnimalsContrast MediaFemaleImage EnhancementImage Interpretation, Computer-AssistedKidneyMagnetic Resonance ImagingMiceReproducibility of ResultsSensitivity and SpecificityContrast MediaCoordination Complexeseuropium DOTA-tetraglycinate

Identifiers

PMID22213371
PMCPMC3422602

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.