Evidence map›Paper›PMID 22206453›Full record

ArticleAnalytical chemistry2012

Constant flow-driven microfluidic oscillator for different duty cycles.

Sung-Jin Kim, Ryuji Yokokawa, Sasha Cai Lesher-Perez, Shuichi Takayama

Abstract read
In one paragraph

Article in Analytical chemistry, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 48 citations in OpenAlex.

  1. Periodic Flows in Microfluidics.Small (Weinheim an der Bergstrasse, Germany) · 2024
    Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Pneumatic oscillator circuits for timing and control of integrated microfluidics.Proceedings of the National Academy of Sciences of the United States of America · 2013
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 3 countries.

Sung-Jin KimDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States.
Ryuji Yokokawa
Sasha Cai Lesher-Perez
Shuichi Takayama
University of Michigan–Ann Arbor · USUlsan National Institute of Science and Technology · KR

Funding

Cellular Biotechnology Training Program (CBTP)T32GM008353 · NIGMS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI SCHWENDEMAN, ANNA · 1991 to 2021
$9.3M
Microfluidic Tissue Engineering of Small Airway InjuriesR01HL084370 · NHLBI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI TAKAYAMA, SHUICHI · 2006 to 2010
$2.8M
Cellular Biotechnology Training Program (CBTP) - Years 31-35T32GM145304 · NIGMS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI Guizhi Zhu · 2022 to 2026
$2.6M
Microfluidic Analysis of Oscillatory Signaling Pathways Using Phase LockingR01GM096040 · NIGMS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI TAKAYAMA, SHUICHI · 2011 to 2014
$1.1M
NHLBI NIH HHS HL084370-05NHLBI NIH HHS R01 HL084370NIGMS NIH HHS GM096040-01NIGMS NIH HHS R01 GM096040NIGMS NIH HHS T32 GM008353NIGMS NIH HHS T32 GM145304
6 · The paper itself

Abstract

This paper presents microfluidic devices that autonomously convert two constant flow inputs into an alternating oscillatory flow output. We accomplish this hardware embedded self-control programming using normally closed membrane valves that have an inlet, an outlet, and a membrane-pressurization chamber connected to a third terminal. Adjustment of threshold opening pressures in these 3-terminal flow switching valves enabled adjustment of oscillation periods to between 57 and 360 s with duty cycles of 0.2-0.5. These values are in relatively good agreement with theoretical values, providing the way for rational design of an even wider range of different waveform oscillations. We also demonstrate the ability to use these oscillators to perform temporally patterned delivery of chemicals to living cells. The device only needs a syringe pump, thus removing the use of complex, expensive external actuators. These tunable waveform microfluidic oscillators are envisioned to facilitate cell-based studies that require temporal stimulation.

Indexed as

AnimalsCell Culture TechniquesCell NucleusCells, CulturedEquipment DesignFlow Injection AnalysisFluorescent DyesMiceMicrofluidicsMuscle, SkeletalFluorescent Dyes

Identifiers

PMID22206453
PMCPMC3264749
OpenAlexW2136820036

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.