Evidence map›Paper›PMID 22174552›Full record

ArticleWorld journal of gastroenterology2011

Experimental study of destruction to porcine spleen in vivo by microwave ablation.

Fei Gao, Yang-Kui Gu, Jing-Xian Shen, Chang-Lun Li, Xiong-Ying Jiang, Jin-Hua Huang

Open access · hybridAbstract read
In one paragraph

Article in World journal of gastroenterology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 8 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Fei GaoState Key Laboratory of Oncology in South China, Guangzhou 510060, Guangdong Province, China.
Yang-Kui Gu
Jing-Xian Shen
Chang-Lun Li
Xiong-Ying Jiang
Jin-Hua Huang
Key Laboratory of Guangdong Province · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo discuss the safety, feasibility and regularity of destruction to porcine spleen in vivo with congestion and tumescence by microwave ablation (MWA).

methodsLigation of the splenic vein was used to induce congestion and tumescence in vivo in five porcine spleens, and microwave ablation was performed 2-4 h later. A total of 56 ablation points were ablated and the ablation powers were 30-100 W. The ablation time (1, 2, 3, 4, 5, 6, 7, 8, 9 and 10 min) was performed at a power of 60 W. After ablation, the ablation size was measured in pigs A, C, D and E and spleen resection. In pig B, the ablation size was measured and 2 ablation points were sent for pathology analysis and all tissues were sutured following ablation. Pig B was killed 1 wk later and the ablation points were sent for pathology analysis. Bleeding, tissue carbonization surrounding electrodes, and pathological changes were observed, and the effect on destruction volume relative to different ablation powers, times and positions was analyzed.

resultsThe incidence of bleeding (only small am-ounts, < 20 mL) in the course of ablation was 5.4% (3/56) and was attributed to tissue carbonization surrounding electrodes, which also exhibited an incidence of 5.4% (3/56). The destruction volume was influenced by different ablation powers, times and points. It showed that the ablation lesion size increased with increased ablation time, from 1 to 10 min, when the ablation power was 60 W. Also, the ablation lesion size increased with the increase of ablation power, ranging from 30 to 100 W when the ablation time was set to 3 min. A direct correlation was seen between the destruction volume and ablation time by the power of 60 W (r = 0.97542, P < 0.0001, and also between the destruction volume and ablation powers at an ablation time of 3 min (r = 0.98258, P < 0.0001). The destruction volume of zone II (the extra-2/3 part of the spleen, relative to the first or second class vascular branches), which was near the hilum of the spleen, was noteably larger than the destruction volume of zoneI(the intra-1/3 part of the spleen) which was distal from the hilum of the spleen (P = 0.0015). Pathological changes of ablation occurring immediately and 1 wk after MWA showed large areas of coagulation. Immediately following ablation, intact spleen tissues were observed in the areas of coagulation necrosis, mainly around arterioles, and there were no obvious signs of hydropsia and inflammation, while 1 wk following the ablation, the coagulation necrosis was well distributed and complete, as many nuclear fragmentations were detected, and there were obvious signs of hydropsia and inflammation.

conclusionIn vivo treatment of congestion and tumescence in the spleen using microwave ablation of water-cooled antenna is a safe and feasible method that is minimally invasive.

Indexed as

MicrowavesAnimalsCatheter AblationFemaleHypersplenismMaleSpleenSplenomegalySwineExperimental studyIn vivoMicrowave ablationPorcine spleenWater-cooled antenna

Identifiers

PMID22174552
PMCPMC3236583
OpenAlexW2110336555

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.