Evidence map›Paper›PMID 22169667›Full record

ArticleJournal of vascular surgery2012

In vivo PEG modification of vascular surfaces for targeted delivery.

Timothy E Deglau, Timothy M Maul, Flordeliza S Villanueva, William R Wagner

Abstract readComparative Study
In one paragraph

Article in Journal of vascular surgery, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Local drug delivery to prevent restenosis.Journal of vascular surgery · 2013
    Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Timothy E DeglauDepartment of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA.
Timothy M Maul
Flordeliza S Villanueva
William R Wagner

Funding

UNIVERSITY OF PITTSBURGH CLINICAL AND TRANSLATIONAL SCIENCE INSTITUTE: BPCAUL1RR024153 · NCRR · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI REIS, STEVEN E · 2006 to 2011
$73.9M
University of Pittsburgh Clinical and Translational Science InstituteUL1TR000005 · NCATS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI REIS, STEVEN E · 2012 to 2015
$50.8M
MOLECULAR BARRIERS TO THROMBOSIS ON TISSUE SURFACESR29HL058617 · NHLBI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI WAGNER, WILLIAM R · 1998 to 2002
$310k
NCATS NIH HHS UL1 TR000005NCRR NIH HHS UL1 RR024153NHLBI NIH HHS HL58617NHLBI NIH HHS R29 HL058617
6 · The paper itself

Abstract

objectiveThrombosis and restenosis remain problematic for many intravascular procedures. Previously, it has been demonstrated that modifying an injured vascular surface with a protein-reactive polymer could block undesirable platelet deposition. As an added benefit, it would be advantageous if one could target therapeutics to the injured site. This study investigates a site-specific delivery system to target microspheres to vascular surfaces modified with a reactive polyethylene glycol tagged with biotin.

methodsRabbit femoral arteries were injured with a 2F embolectomy catheter. Modification of the vascular surface was achieved using a channeled balloon catheter or small-diameter tube. Microspheres were injected intravenously through catheterization of the ear vein. Polymer modification on the injured surface and delivery of microspheres was quantified using epifluorescence microscopy at 0, 24, 48, and 72 hours.

resultsPolymer modification of the vascular surface could be achieved using a channeled drug delivery catheter or small-diameter tube with similar results. Maximum polymer coverage occurred at 0 hours and decreased to 85% maximal at 24 hours, 72% at 48 hours, and 67% at 72 hours. The initial number of microspheres per mm(2) binding to modified, injured arteries was 304 versus 141 for the unmodified, damaged control (P < .01). At subsequent times, the number of adherent microspheres to modified, injured arteries decreased by 50%, 70%, and 84% at 24, 48, and 72 hours, respectively; while nonspecific binding to unmodified, injured arteries quickly decreased by 93%. Initial microsphere binding to modified, healthy arteries was 153 microspheres/mm(2) as opposed to 26 microspheres/mm(2) for the unmodified, healthy controls (P < .01).

conclusionsChemical modification of injured vessels following intravascular procedures can be readily accomplished in vivo to create a substrate for targeted delivery systems. As a proof of concept, targeted microspheres preferentially adhered to polymer-modified surfaces as opposed to injured, unmodified, or healthy vascular surfaces.

Indexed as

MicrospheresAnimalsCatheterizationDisease Models, AnimalDrug Delivery SystemsFemaleFemoral ArteryGraft Occlusion, VascularMicroscopy, FluorescencePolyethylene GlycolsPostoperative ComplicationsRabbitsRandom AllocationReference ValuesSensitivity and SpecificitySurface PropertiesPolyethylene Glycols

Identifiers

PMID22169667
PMCPMC3319259

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.