ArticleSensors (Basel, Switzerland)2010
Electrochemical aptasensor for endocrine disrupting 17β-estradiol based on a poly(3,4-ethylenedioxylthiopene)-gold nanocomposite platform.
Article in Sensors (Basel, Switzerland), 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed.
- Editors' Choice-Review-The Future of Carbon-Based Neurochemical Sensing: A Critical Perspective.ECS sensors plus · 2023Review
- Advances on Hormones and Steroids Determination: A Review of Voltammetric Methods since 2000.Membranes · 2022Review
- Role of Estradiol Hormone in Human Life and Electrochemical Aptasensing of 17β-Estradiol: A Review.Biosensors · 2022Review
- Polymeric Nanocomposites for Environmental and Industrial Applications.International journal of molecular sciences · 2022Review
- Article
- Electrochemical DNA Sensor Based on Acridine Yellow Adsorbed on Glassy Carbon Electrode.Sensors (Basel, Switzerland) · 2021Article
- Article
- A Sensitive Impedimetric Aptasensor Based on Carbon Nanodots Modified Electrode for Detection of 17ß-Estradiol.Nanomaterials (Basel, Switzerland) · 2020Article
- Liquid Contact-Selective Potentiometric Sensor Based on Imprinted Polymeric Beads Towards 17β-Estradiol Determination.Polymers · 2020Article
- Impedimetric Biosensors for Detecting Vascular Endothelial Growth Factor (VEGF) Based on Poly(3,4-ethylene dioxythiophene) (PEDOT)/Gold Nanoparticle (Au NP) Composites.Frontiers in chemistry · 2019Article
- Review
- Article
- Review
- Biomedical Probes Based on Inorganic Nanoparticles for Electrochemical and Optical Spectroscopy Applications.Sensors (Basel, Switzerland) · 2015Review
- Diverse applications of electronic-nose technologies in agriculture and forestry.Sensors (Basel, Switzerland) · 2013Review
- Biotin-functionalized semiconducting polymer in an organic field effect transistor and application as a biosensor.Sensors (Basel, Switzerland) · 2012Article
Corrections and comments
- Erratum issued
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A simple and highly sensitive electrochemical DNA aptasensor with high affinity for endocrine disrupting 17β-estradiol, was developed. Poly(3,4-ethylenedioxylthiophene) (PEDOT) doped with gold nanoparticles (AuNPs) was electrochemically synthesized and employed for the immobilization of biotinylated aptamer towards the detection of the target. The diffusion coefficient of the nanocomposite was 6.50 × 10(-7) cm(2) s(-1), which showed that the nanocomposite was highly conducting. Electrochemical impedance investigation also revealed the catalytic properties of the nanocomposite with an exchange current value of 2.16 × 10(-4) A, compared to 2.14 × 10(-5) A obtained for the bare electrode. Streptavidin was covalently attached to the platform using carbodiimide chemistry and the aptamer immobilized via streptavidin-biotin interaction. The electrochemical signal generated from the aptamer-target molecule interaction was monitored electrochemically using cyclic voltammetry and square wave voltammetry in the presence of [Fe(CN)(6)](-3/-4) as a redox probe. The signal observed shows a current decrease due to interference of the bound 17β-estradiol. The current drop was proportional to the concentration of 17β-estradiol. The PEDOT/AuNP platform exhibited high electroactivity, with increased peak current. The platform was found suitable for the immobilization of the DNAaptamer. The aptasensor was able to distinguish 17β-estradiol from structurally similar endocrine disrupting chemicals denoting its specificity to 17β-estradiol. The detectable concentration range of the 17β-estradiol was 0.1 nM-100 nM, with a detection limit of 0.02 nM.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.