Evidence map›Paper›PMID 22163154›Full record

ArticleSensors and actuators. A, Physical2011

A Realtime and Continuous Assessment of Cortisol in ISF Using Electrochemical Impedance Spectroscopy.

Manju Venugopal, Sunil K Arya, Ganna Chornokur, Shekhar Bhansali

Abstract read
In one paragraph

Article in Sensors and actuators. A, Physical, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed
1.5field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed, 94 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Article
  6. Review
  7. Review
  8. Article
  9. Review
  10. Review
  11. Review
  12. Review
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Manju VenugopalGuided Therapeutics Inc., 5835 Peachtree Corners East, Suite D, Norcross, GA 30092, Unites States.
Sunil K Arya
Ganna Chornokur
Shekhar Bhansali
University of South Florida · US

Funding

Instacortisol: A realtime and continuous assessment of cortisol in ISFR44MH085474 · NIMH · GUIDED THERAPEUTICS · PI VENUGOPAL, MANJU GROVER · 2011 to 2012
$1.1M
InstaCortisol:A realtime and continuous assessment of Cortisol in ISFR43MH085474 · NIMH · GUIDED THERAPEUTICS · PI VENUGOPAL, MANJU GROVER · 2009 to 2010
$196k
NIMH NIH HHS R43 MH085474
6 · The paper itself

Abstract

This study describes the functioning of a novel sensor to measure cortisol concentration in the interstitial fluid (ISF) of a human subject. ISF is extracted by means of vacuum pressure from micropores created on the stratum corneum layer of the skin. The pores are produced by focusing a near infrared laser on a layer of black dye material attached to the skin. The pores are viable for approximately three days after skin poration. Cortisol measurements are based on electrochemical impedance (EIS) technique. Gold microelectrode arrays functionalized with Dithiobis (succinimidyl propionate) self-assembled monolayer (SAM) have been used to fabricate an ultrasensitive, disposable, electrochemical cortisol immunosensor. The biosensor was successfully used for in-vitro measurement of cortisol in ISF. Tests in a laboratory setup show that the sensor exhibits a linear response to cortisol concentrations in the range 1 pm to 100 nM. A small pilot clinical study showed that in-vitro immunosensor readings, when compared with commercial evaluation using enzyme-linked immunoassay (ELISA) method, correlated well with cortisol levels in saliva and ISF. Further, circadian rhythm could be established between the subject's ISF and the saliva samples collected over 24 hours time-period. Cortisol levels in ISF were found reliably higher than in saliva. This Research establishes the feasibility of using impedance based biosensor architecture for a disposable, wearable cortisol detector. The projected commercial in-vivo real-time cortisol sensor device, besides being minimally invasive, will allow continuous ISF harvesting and cortisol monitoring over 24 hours even when the subject is asleep. Forthcoming, this sensor could be interfaced to a wireless health monitoring system that could transfer sensor data over existing wide-area networks such as the internet and a cellular phone network to enable real-time remote monitoring of subjects.

Identifiers

PMID22163154
PMCPMC3234992
OpenAlexW2021895870

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.