High resolution dual detector volume-of-interest cone beam breast CT--Demonstration with a bench top system.

Youtao Shen, Ying Yi, Yuncheng Zhong, Chao-Jen Lai, Xinming Liu, Zhicheng You, Shuaiping Ge, Tianpeng Wang, Chris C Shaw

Abstract read
In one paragraph

Article in Medical physics, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. A general method for cupping artifact correction of cone-beam breast computed tomography images.International journal of computer assisted radiology and surgery · 2016
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Youtao ShenDepartment of Imaging Physics, The University of Texas M. D. Anderson Cancer Center, Houston, Texas 77030, USA.
Ying Yi
Yuncheng Zhong
Chao-Jen Lai
Xinming Liu
Zhicheng You
Shuaiping Ge
Tianpeng Wang
Chris C Shaw

Funding

aSi/CsI FP digital chest imaging with scatter rejectionR01EB000117 · NIBIB · UNIVERSITY OF TEXAS MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2002 to 2005
$2.3M
Optimized Digital Mammography with an a-Se FP ImagerR01CA104759 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2004 to 2007
$2.2M
A Dual Resolution Cone Beam CT System for 3-D Breast ImagingR33CA124585 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2008 to 2010
$1.3M
A Dual Resolution Cone Beam CT System for 3-D Breast ImagingR21CA124585 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2007 to 2007
$234k
NCI NIH HHS CA 104759NCI NIH HHS CA 124585NCI NIH HHS CA 13852NCI NIH HHS R01 CA104759NCI NIH HHS R21 CA124585NCI NIH HHS R33 CA124585NIBIB NIH HHS EB00117NIBIB NIH HHS R01 EB000117
6 · The paper itself

Abstract

purposeIn this study, we used a small field high resolution detector in conjunction with a full field flat panel detector to implement and investigate the dual detector volume-of-interest (VOI) cone beam breast computed tomography (CBCT) technique on a bench-top system. The potential of using this technique to image small calcifications without increasing the overall dose to the breast was demonstrated. Significant reduction of scatter components in the high resolution projection image data of the VOI was also shown.

methodsWith the regular flat panel based CBCT technique, exposures were made at 80 kVp to generate an air kerma of 6 mGys at the isocenter. With the dual detector VOI CBCT technique, a high resolution small field CMOS detector was used to scan a cylindrical VOI (2.5 cm in diameter and height, 4.5 cm off-center) with collimated x-rays at four times of regular exposure level. A flat panel detector was used for full field scan with low x-ray exposures at half of the regular exposure level. The low exposure full field image data were used to fill in the truncated space in the VOI scan data and generate a complete projection image set. The Feldkamp-Davis-Kress (FDK) filtered backprojection algorithm was used to reconstruct high resolution images for the VOI. Two scanning techniques, one breast centered and the other VOI centered, were implemented and investigated. Paraffin cylinders with embedded thin aluminum (Al) wires were imaged and used in conjunction with optically stimulated luminescence (OSL) dose measurements to demonstrate the ability of this technique to image small calcifications without increasing the mean glandular dose (MGD).

resultsUsing exposures that produce an air kerma of 6 mGys at the isocenter, the regular CBCT technique was able to resolve the cross-sections of Al wires as thin as 254 μm in diameter in the phantom. For the specific VOI studied, by increasing the exposure level by a factor of 4 for the VOI scan and reducing the exposure level by a factor of 2 for the full filed scan, the dual-detector CBCT technique was able to resolve the cross-sections of Al wires as thin as 152 μm in diameter. The CNR evaluated for the entire Al wire cross-section was found to be improved from 5.5 in regular CBCT to 14.4 and 16.8 with the breast centered and VOI centered scanning techniques, respectively. Even inside VOI center, the VOI scan resulted in significant dose saving with the dose reduced by a factor of 1.6 at the VOI center. Dose saving outside the VOI was substantial with the dose reduced by a factor of 7.3 and 7.8 at the breast center for the breast centered and VOI centered scans, respectively, when compared to full field scan at the same exposure level. The differences between the two dual detector techniques in terms of dose saving and scatter reduction were small with VOI scan at 4× exposure level and full field scan at 0.5 × exposure level. The MGDs were only 94% of that from the regular CBCT scan.

conclusionsFor the specific VOI studied, the dual detector VOI CBCT technique has the potential to provide high quality images inside the VOI with MGD similar to or even lower than that of full field breast CBCT. It was also found that our results were compromised by the use of inadequate detectors for the VOI scan. An appropriately selected detector would better optimize the image quality improvement that can be achieved with the VOI CBCT technique.

Indexed as

Breast NeoplasmsCone-Beam Computed TomographyEquipment DesignEquipment Failure AnalysisFemaleHumansImaging, Three-DimensionalMammographyPhantoms, ImagingPilot ProjectsRadiographic Image EnhancementRadiographic Image Interpretation, Computer-AssistedReproducibility of ResultsSensitivity and SpecificityTomography, X-Ray ComputedTransducers

Identifiers

PMID22149826
PMCPMC3230641

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.