ArticleBiomedical microdevices2012

Development of a wireless intra-vaginal transducer for monitoring intra-abdominal pressure in women.

Tanner J Coleman, Jens C Thomsen, Sean D Maass, Yvonne Hsu, Ingrid E Nygaard, Robert W Hitchcock

Open access · greenAbstract read
In one paragraph

Article in Biomedical microdevices, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
34citing papers in PubMed, 1 pooled it
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

34 citing papers in PubMed, 1 synthesis or guideline pooled it, 45 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Review
  5. Article
  6. Observational
  7. Article
  8. Article
  9. Article
  10. Article
  11. Intrinsic factors contributing to elevated intra-abdominal pressure.Computer methods in biomechanics and biomedical engineering · 2023
    Article
  12. Article
  13. Article
  14. Long-Range Detection of a Wirelessly Powered Resistive Transducer.IEEE transactions on instrumentation and measurement · 2022
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Tanner J ColemanDepartment of Bioengineering, University of Utah, 20 S. 2030 E, Rm. 186, Salt Lake City, UT 84112, USA.
Jens C Thomsen
Sean D Maass
Yvonne Hsu
Ingrid E Nygaard
Robert W Hitchcock
University of Utah · US

Funding

WIRELESS REMOTE ABDOMINAL PRESSURE SYSTEM: DEVELOPING A MORE COMPREHENSIVE UNDERSR01HD061787 · NICHD · UNIVERSITY OF UTAH · PI NYGAARD, INGRID E · 2009 to 2013
$1.8M
NICHD NIH HHS R01 HD061787NICHD NIH HHS R01HD061787
6 · The paper itself

Abstract

Pelvic floor disorders (PFD) affect one of every four women in the United States. Elevated intra-abdominal pressure (IAP) during daily activity or strenuous physical activity has been identified as a risk factor in the prevalence of PFD. However, the relationship between IAP and physical activity is poorly understood and oftentimes activity restrictions are prescribed by physicians without clinical evidence linking various activities to elevated IAP. There are currently no pressure transducers capable of monitoring IAP non-invasively out of a clinical environment. To overcome this shortcoming, a novel intra-vaginal pressure transducer (IVT) was developed to continuously monitor IAP. Improvements were made to the first generation IVT by incorporating wireless capability to enhance the device's mobility while creating a more robust IAP monitoring system. To ensure the changes maintained the functionality of the original device design, comparison testing with standard clinical pressure transducers in both bench top and clinical settings was conducted. The wireless device was found to have high linearity, robust signal transmission, and dynamic response that outperforms the clinical standard rectal transducer and is similar to the original first generation non-wireless design. The wireless IVT presented here is a mobile wireless device capable of measuring, storing and transmitting IAP data during various physical activities.

Indexed as

Transducers, PressureAbdomenBiosensing TechniquesEquipment DesignFemaleHumansMonitoring, PhysiologicPelvic Floor DisordersRectumReproducibility of ResultsVaginaWireless Technology

Identifiers

PMID22147020
PMCPMC3303945
OpenAlexW2013117402

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.