ArticleClinical oral investigations2012
Assessment of lipopolysaccharide microleakage at conical implant-abutment connections.
Article in Clinical oral investigations, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 40 citations in OpenAlex.
- Evaluation of Microgap Size and Microbial Microleakage at the Implant Fixture-Abutment Interface in Original and Compatible Abutments.BioMed research international · 2025Article
- In Vitro Bacterial Leakage at the Implant-Abutment Connection of Two Dental Implant Systems with Internal Connection.Frontiers in dentistry · 2020Article
- The influence of implant-abutment connection on the screw loosening and microleakage.International journal of implant dentistry · 2018Article
- Microleakage at the Different Implant Abutment Interface: A Systematic Review.Journal of clinical and diagnostic research : JCDR · 2017Review
- In vitro analysis of the microbiological sealing of tapered implants after mechanical cycling.Clinical oral investigations · 2016Article
- Leakage evaluation of original and compatible implant-abutment connections: In vitro study using Rhodamine B.Journal of dental biomechanics · 2014Article
- In vitro evaluation of leakage at implant-abutment connection of three implant systems having the same prosthetic interface using rhodamine B.International journal of dentistry · 2014Article
- Analysis of the intraimplant microflora of two-piece dental implants.Clinical oral investigations · 2013Article
- Analytical and experimental position stability of the abutment in different dental implant systems with a conical implant-abutment connection.Clinical oral investigations · 2013Article
- A three-dimensional finite element analysis of a passive and friction fit implant abutment interface and the influence of occlusal table dimension on the stress distribution pattern on the implant and surrounding bone.Journal of Indian Prosthodontic SocietyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThe aim of this in vitro study was to assess lipopolysaccharide microleakage at conical implant-abutment connections of two-piece dental implants in terms of the expression levels of genes involved in lipopolysaccharide-mediated proinflammatory cytokine production. MATERIALS AND
methodsTwo implant systems with conical implant-abutment connections were inoculated with lipopolysaccharide and submerged in human whole blood. Positive-control blood samples (without implants) were stimulated with 4 μg/ml, 2 μg/ml, 200 ng/ml, and 20 ng/ml lipopolysaccharide. Sampling was performed after 1, 8, and 24 h of incubation. Changes of gene expression levels of Toll-like receptor 9, tumor necrosis factor-α, nuclear factor kappa light chain enhancer of activated B cells, interleukin-1β, and interferon-γ were assessed by real-time quantitative PCR. In addition, protein expression levels of interleukin-6, tumor necrosis factor-α, interleukin-1β, and interferon-γ were determined by immunoassay.
resultsChanges in cytokine expression at the genomic and proteomic levels indicated lipopolysaccharide leakage at the interfaces of both tested implant systems, although some implants showed no sign of microleakage. Any tested concentration of lipopolysaccharide stimulated similar gene expression.
conclusionsConical implant-abutment connections of two-piece dental implants do not prevent microleakage on a molecular level. Changes in lipopolysaccharide-induced proinflammatory cytokine gene expression facilitate the detection of lipopolysaccharide microleakage at implant-abutment interfaces. CLINICAL RELEVANCE: Small amounts of lipopolysaccharide released from intra-implant cavities can stimulate a detectable immunological response in human whole blood and may induce alveolar bone resorption via the osteoclast-activating pathway.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.