Evidence map›Paper›PMID 22127361›Full record

ArticleStrahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]2011

Procedure for creating a three-dimensional (3D) model for superficial hyperthermia treatment planning.

Marianne Linthorst, Tomas Drizdal, Hans Joosten, Gerard C van Rhoon, Jacoba van der Zee

Abstract read
PubMed Publisher
In one paragraph

Article in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Trial
  2. Article
  3. Temperature simulations in hyperthermia treatment planning of the head and neck region: rigorous optimization of tissue properties.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2014
    Article
  4. Benefit of replacing the Sigma-60 by the Sigma-Eye applicator. A Monte Carlo-based uncertainty analysis.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2013
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Marianne LinthorstErasmus MC Rotterdam, Department of Radiation Oncology, Hyperthermia Unit, Rotterdam, The Netherlands. m.linthorst@erasmusmc.nl
Tomas Drizdal
Hans Joosten
Gerard C van Rhoon
Jacoba van der Zee
Erasmus University Rotterdam · NLErasmus MC · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo make a patient- and treatment-specific computed tomography (CT) scan and to create a three-dimensional (3D) patient model for superficial hyperthermia treatment planning (SHTP). PATIENTS, MATERIALS, AND

methodsPatients with recurrent breast adenocarcinoma in previously irradiated areas referred for radiotherapy (RT) and hyperthermia (HT) treatment and giving informed consent were included. After insertion of the thermometry catheters in the treatment area, a CT scan in the treatment position was made.

resultsA total of 26 patients have been, thus far, included in the study. During the study period, five types of adjustments were made to the procedure: (1) marking the RT field with radioopaque markers, (2) making the CT scan after the first HT treatment instead of before, (3) using an air- and foam-filled (dummy) water bolus, (4) a change to radiolucent catheters for which radioopaque markers were needed, and (5) marking the visible/palpable extent of the tumor with radioopaque markers, if necessary. With these adjustments, all necessary information is visible on the CT scan. Each CT slice was automatically segmented into muscle, fat, bone, and air. RT field, catheters, applicators, and tumor lesions, if indicated, were outlined manually using the segmentation program iSeg. Next the model was imported into SEMCAD X, a 3D electromagnetic field simulator.

conclusionUsing the final procedure to obtain a patient- and treatment-specific CT scan, it is possible to create a 3D model for SHTP.

Indexed as

AdenocarcinomaBreast NeoplasmsCombined Modality TherapyFemaleHumansHyperthermia, InducedImage Processing, Computer-AssistedMultidetector Computed TomographyNeoplasm Recurrence, LocalPatient PositioningRadiotherapy Planning, Computer-AssistedTomography, X-Ray Computed

Identifiers

PMID22127361
OpenAlexW1777656261

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.