Evidence map›Paper›PMID 22127360›Full record

ArticleStrahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]2011

Impact of gantry rotation time on plan quality and dosimetric verification--volumetric modulated arc therapy (VMAT) vs. intensity modulated radiotherapy (IMRT).

Marlies Pasler, Holger Wirtz, Johannes Lutterbach

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
5.7field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 25 citations in OpenAlex.

  1. Clinical and dosimetric evaluation of RapidArc versus standard sliding window IMRT in the treatment of head and neck cancer.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2015
    Trial
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Influence of metallic dental implants and metal artefacts on dose calculation accuracy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2015
    Article
  10. Article
  11. New possibilities for volumetric-modulated arc therapy using the Agility™ 160-leaf multileaf collimator.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2014
    Article
  12. Planning study to compare dynamic and rapid arc techniques for postprostatectomy radiotherapy of prostate cancer.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2014
    Article
  13. Article
  14. Article
  15. Node-positive left-sided breast cancer: does VMAT improve treatment plan quality with respect to IMRT?Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2013
    Article
  16. Article
  17. Dosimetric effect of limited aperture multileaf collimator on VMAT plan quality: A study of prostate and head-and-neck cancers.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Marlies PaslerGemeinschaftspraxis für Strahlentherapie Singen-Friedrichshafen, Friedrichshafen, Germany. pasler@strahlentherapie-fn.de
Holger Wirtz
Johannes Lutterbach
Praxis für Humangenetik · DEUniversitätsklinik für Strahlentherapie · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeTo compare plan quality criteria and dosimetric accuracy of step-and-shoot intensity-modulated radiotherapy (ss-IMRT) and volumetric modulated arc radiotherapy (VMAT) using two different gantry rotation times. PATIENTS AND

methodsThis retrospective planning study based on 20 patients was comprised of 10 prostate cancer (PC) and 10 head and neck (HN) cancer cases. Each plan contained two target volumes: a primary planning target volume (PTV) and a boost volume. For each patient, one ss-IMRT plan and two VMAT plans at 90 s (VMAT90) and 120 s (VMAT120) per arc were generated with the Pinnacle© planning system. Two arcs were provided for the PTV plans and a single arc for boost volumes. Dosimetric verification of the plans was performed using a 2D ionization chamber array placed in a full scatter phantom.

resultsVMAT reduced delivery time and monitor units for both treatment sites compared to IMRT. VMAT120 vs. VMAT90 increased delivery time and monitor units in PC plans without improving plan quality. For HN cases, VMAT120 provided comparable organs at risk sparing and better target coverage and conformity than VMAT90. In the VMAT plan verification, an average of 97.1% of the detector points passed the 3 mm, 3% γ criterion, while in IMRT verification it was 98.8%.

conclusionVMAT90, VMAT120, and IMRT achieved comparable treatment plans. Slower gantry movement in VMAT120 plans only improves dosimetric quality for highly complex targets.

Indexed as

Quality Assurance, Health CareRadiometryHumansLymphatic IrradiationMaleOrgans at RiskOtorhinolaryngologic NeoplasmsProstatic NeoplasmsRadiotherapy, AdjuvantRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-Assisted

Identifiers

PMID22127360
OpenAlexW64306167

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked