ArticleNeuroinformatics2012
Automatic segmentation of ventricular cerebrospinal fluid from ischemic stroke CT images.
Article in Neuroinformatics, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Automated Ventricle Assessment via Three-dimensional Anatomical Reconstruction (AVA-TAR): a computational toolkit for autonomous lateral ventricle assessment in preclinical hydrocephalus models.bioRxiv : the preprint server for biology · 2026Article
- Deep learning-based segmentation of brain parenchyma and ventricular system in CT scans in the presence of anomalies.Frontiers in neuroimaging · 2023Article
- AI-based medical e-diagnosis for fast and automatic ventricular volume measurement in patients with normal pressure hydrocephalus.Neural computing & applications · 2022Article
- Human Brain Atlases in Stroke Management.Neuroinformatics · 2020Article
- Automated CT registration tool improves sensitivity to change in ventricular volume in patients with shunts and drains.The British journal of radiology · 2020Article
- Systematic and Comprehensive Automated Ventricle Segmentation on Ventricle Images of the Elderly Patients: A Retrospective Study.Frontiers in aging neuroscience · 2020Article
- Article
- Recommendations for Processing Head CT Data.Frontiers in neuroinformatics · 2019Article
- Quantitative estimation of a ratio of intracranial cerebrospinal fluid volume to brain volume based on segmentation of CT images in patients with extra-axial hematoma.The neuroradiology journal · 2017Article
- Z-score-based semi-quantitative analysis of the volume of the temporal horn of the lateral ventricle on brain CT images.Radiological physics and technology · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Accurate segmentation of ventricular cerebrospinal fluid (CSF) regions in stroke CT images is important in assessing stroke patients. Manual segmentation is subjective, time consuming and error prone. There are currently no methods dedicated to extracting ventricular CSF regions in stroke CT images. 102 ischemic stroke CT scans (slice thickness between 3 and 6 mm, voxel size in the axial plane between 0.390 and 0.498 mm) were acquired. An automated template-based algorithm is proposed to extract ventricular CSF regions which accounts for the presence of ischemic infarct regions, image noise, and variations in orientation. First, template VT(2) is registered to the scan using landmark-based piecewise linear scaling and then template VT(1) is used to further refine the registration by partial segmentation of the fourth ventricle. A region of interest (ROI) is found using the registered VT(2). Automated thresholding is then applied to the ROI and the artifacts are removed in the final phase. Sensitivity, dice similarity coefficient, volume error, conformity and sensibility of segmentation results were 0.74 ± 0.12, 0.8 ± 0.09, 0.16 ± 0.11, 0.45 ± 0.39, 0.88 ± 0.09, respectively. The processing time for a 512 × 512 × 30 CT scan takes less than 30 s on a 2.49 GHz dual core processor PC with 4 GB RAM. Experiments with clinical stroke CT scans showed that the proposed algorithm can generate acceptable results in the presence of noise, size variations and orientation differences of ventricular systems and in the presence of ischemic infarcts.
Indexed as
Identifiers
22125015What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.