Evidence map›Paper›PMID 22096443›Full record

ArticleThe Iowa orthopaedic journal2011

Cervical laminoplasty construct stability: an experimental and finite element investigation.

Srinivas C Tadepalli, Anup A Gandhi, Douglas C Fredericks, Nicole M Grosland, Joseph Smucker

Open access · greenAbstract read
In one paragraph

Article in The Iowa orthopaedic journal, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Lamina Abrasion Caused by High-Speed Drill in Unilateral Door Cervical Laminoplasty: A Clinical Investigation.Medical science monitor : international medical journal of experimental and clinical research · 2023
    Article
  4. Article
  5. Cervical Laminoplasty: The History and the Future.Neurologia medico-chirurgica · 2015
    Review
  6. Article
  7. Toward the development of virtual surgical tools to aid orthopaedic FE analyses.EURASIP journal on advances in signal processing · 2010
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Srinivas C TadepalliDepartment of Biomedical Engineering, The University of Iowa, Iowa City, USA.
Anup A Gandhi
Douglas C Fredericks
Nicole M Grosland
Joseph Smucker
University of Iowa · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STUDY

designExperimental and finite element investigation of cervical laminoplasty.

objectiveTo determine the stability of the construct post cervical laminoplasty. SUMMARY OF BACKGROUND DATA: Cervical laminoplasty is a widely used technique to widen the spinal canal dimensions without permanently removing the dorsal elements of the cervical spine. Although various laminoplasty procedures have been developed recently, the use of mini-plates to hold the lamina open and prevent restenosis of the spinal cord is a fairly new method and has not been thoroughly investigated.

methodsBiomechanical compression tests and finite element analyses were performed in this study. Sixteen cervical vertebrae (C3 - C6) were isolated from six cadaveric cervical spines (age at death 68 to 91 years; mean 85 years) and were used for compression tests. Out of the 16 vertebrae, four were without any surgical intervention and the remaining 12 were implanted with one of the two laminoplasty plates: open door (OD) graft. Each vertebra was randomly assigned to one of the three groups: OD plate (6), graft plate (6) or intact vertebrae (4). The intact and implanted vertebrae were potted and loaded to failure. Cross-head displacements and the corresponding reaction force throughout the test were recorded to determine the failure loads. A finite element model of the C5 cervical vertebra was created to accommodate the laminoplasty implants. Experimental loading and boundary conditions were simulated and the stress distribution in the lamina was predicted in response to the compressive loads.

resultsA substantial increase in the sagittal canal diameter (27%-33%) and the spinal canal area (31.2%-47%) was observed at all levels. The strength of the implanted specimens was considerably decreased (by six to eight times) as compared to the intact specimens.

conclusionExperimentally obtained data can be combined with mathematical models, such as finite element models, to accurately predict the biomechanical behavior (stresses and strains) of implants and the posterior bone which may not be possible by the use of any other method.

Indexed as

Finite Element AnalysisModels, BiologicalAgedAged, 80 and overBone PlatesCadaverCervical VertebraeCompressive StrengthDecompression, SurgicalHumansLaminectomyPredictive Value of TestsProstheses and ImplantsReference StandardsSpinal CanalWeight-Bearing

Identifiers

PMID22096443
PMCPMC3215137
OpenAlexW1541720971

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.